 浏览型号XB24CZ7RIS-004的Datasheet PDF文件第129页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第130页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第131页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第132页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第134页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第135页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第136页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第137页  
XBee®/XBeePRO® ZB SMT RF Modules  
I/O Commands  
AT  
Name and Description  
Command  
Parameter Range  
Default  
Pull-up/down Resistor. Set/read the bit field that configures the internal pull-up/down  
resistor status for the I/O lines. "1" specifies the pull-up/down resistor is enabled. "0"  
specifies no internal resistors are used. The input will be floating.  
Bits:"  
0 - DIO4 (Pin 24)  
1 - AD3 / DIO3 (Pin 30)  
2 - AD2 / DIO2 (Pin 31)  
3 - AD1 / DIO1 (Pin 32)  
4 - AD0 / DIO0 (Pin 33)  
5 - RTS / DIO6 (Pin 29)  
6 - DTR / Sleep Request / DIO8 (Pin 10)  
7 - DIN / Config (Pin 4)  
8 - Associate / DIO5 (Pin 28)  
9 - On/Sleep / DIO9 (Pin 26)  
10 - DIO12 (Pin 5)  
PR  
0 - 0x7FFF  
0x1FFF  
11 - PWM0 / RSSI / DIO10 (Pin 7)  
12 - PWM1 / DIO11 (Pin 8)  
13 - CTS / DIO7 (Pin 25)  
14 - DOUT / DIO13 (Pin 3)  
Pull-up / down direction. Set/read an internal pull-up or pull-down resistor for the  
corresponding bits in the PR command. If the bit is set, an internal pull-up resistor is  
used. If it is clear, an internal pull-down resistor is used. See the PR command for the bit  
order.  
PD  
0 - 0x7FFF  
0x1FBF  
RSSI PWM Timer. Time the RSSI signal will be output on the PWM after the last RF data  
RP  
0 - 0xFF [x 100 ms]  
0x28 (40d)  
-
reception or APS acknowledgment.. When RP = 0xFF, output will always be on.  
%V  
Supply Voltage. Reads the voltage on the Vcc pin in mV.  
-0x-0xFFFF [read only]  
Voltage Supply Monitoring. The voltage supply threshold is set with the V+ command.  
If the measured supply voltage falls below or equal to this threshold, the supply voltage  
V+  
TP  
will be included in the IO sample set. V+ is set to 0 by default (do not include the supply 0-0xFFFF  
voltage).The units of this command are mV. For example, to include a measurement of  
the supply voltage when it exceeds 3.3 V, set V+ to 3300 = 0xCE4.  
0
-
Reads the module temperature in Degrees Celsius. Accuracy +/- 7 degrees.  
0x0-0xFFFF  
1° C = 0x0001 and -1° C = 0xFFFF. Command is only available on PRO module.  
© 2010 Digi International, Inc.  
133  