 浏览型号XB24CZ7RIS-004的Datasheet PDF文件第124页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第125页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第126页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第127页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第129页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第130页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第131页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第132页  
XBee®/XBeePRO® ZB SMT RF Modules  
Networking Commands  
AT  
Name and Description  
Command  
Parameter Range  
Default  
Node Join Time. Set/Read the time that a Coordinator/Router allows nodes to join.  
This value can be changed at run time without requiring a Coordinator or Router to  
restart. The time starts once the Coordinator or Router has started. The timer is reset  
on power-cycle or when NJ changes.  
For an end device to enable rejoining, NJ should be set less than 0xFF on the device  
that will join. If NJ < 0xFF, the device assumes the network is not allowing joining and  
first tries to join a network using rejoining. If multiple rejoining attempts fail, or if  
NJ=0xFF, the device will attempt to join using association.  
0 - 0xFF   
[x 1 sec]  
0xFF   
(always allows joining)  
NJ  
0 - Channel verification  
disabled  
Channel Verification. Set/Read the channel verification parameter. If JV=1, a router  
will verify the coordinator is on its operating channel when joining or coming up from a  
JV  
power cycle. If a coordinator is not detected, the router will leave its current channel and 1 - Channel verification  
0
attempt to join a new PAN. If JV=0, the router will continue operating on its current  
channel even if a coordinator is not detected.  
enabled  
Network Watchdog Timeout. Set/read the network watchdog timeout value. If NW is  
0 - 0x64FF  
set > 0, the router will monitor communication from the coordinator (or data collector)  
NW  
and leave the network if it cannot communicate with the coordinator for 3 NW periods. [x 1 minute]  
0 (disabled)  
The timer is reset each time data is received from or sent to a coordinator, or if a many-  
to-one broadcast is received.  
(up to over 17 days)  
Join Notification. Set / read the join notification setting. If enabled, the module will  
transmit a broadcast node identification packet on power up and when joining. This  
JN  
action blinks the Associate LED rapidly on all devices that receive the transmission, and 0 - 1  
sends an API frame out the serial port of API devices. This feature should be disabled  
for large networks to prevent excessive broadcasts.  
0
Aggregate Routing Notification. Set/read time between consecutive aggregate route  
broadcast messages. If used, AR should be set on only one device to enable many-to- 0 - 0xFF  
one routing to the device. Setting AR to 0 only sends one broadcast  
AR  
0xFF  