 浏览型号XB24CZ7RIS-004的Datasheet PDF文件第119页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第120页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第121页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第122页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第124页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第125页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第126页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第127页  
XBee®/XBeePRO® ZB SMT RF Modules  
In the above example, the Frame Control field (offset 23) was constructed as follows:  
Name  
Frame Type  
Bits Example Value Description  
0-1  
2
00 - Command acts across the entire profile  
Manufacturer Specific  
Direction  
0 - The manufacturer code field is omitted from the ZCL Frame Header.  
0 - The command is being sent from the client side to the server side.  
0 - Default response not disabled  
3
Disable Default Response  
Reserved  
4
5-7  
Set to 0.  
See the ZigBee Cluster Library specification for details.  
Sending Public Profile Commands with the API  
Commands in public profiles such as Smart Energy and Home Automation can be sent with the XBee API using the  
Explicit Transmit API frame (0x11). Sending public profile commands with the Explicit Transmit API frame requires  
some formatting of the data payload field. Most of the public profile commands fit into the ZigBee Cluster Library  
(ZCL) architecture as described in the previous section.  
The following table shows how the Explicit API frame can be used to send a demand response and load control  
message (cluster ID 0x701) in the smart energy profile (profile ID 0x0109) in the revision 14 Smart Energy  
specification. The message will be a "Load Control Event" (command ID 0x00) and will be sent to a device with 64-  
bit address of 0x0013A200 40401234 with a 16-bit address of 0x5678. The event will start a load control event for  
water heaters and smart appliances, for a duration of 1 minute, starting immediately.  
Note: When sending public profile commands, the AO command should be set to 1 to enable the explicit receive API  
frame. This will provide indication of the source 64- and 16-bit addresses, cluster ID, profile ID, and endpoint  
information for each received packet. This information is required to properly decode received data.  
© 2010 Digi International, Inc.  
123