 浏览型号XB24CZ7RIS-004的Datasheet PDF文件第97页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第98页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第99页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第100页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第102页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第103页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第104页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第105页  
XBee®/XBeePRO® ZB SMT RF Modules  
Frame Fields  
Offset Example  
0 0x7E  
Description  
Start Delimiter  
Length  
MSB 1 0x00  
LSB 2 0x04  
3 0x08  
Number of bytes between the length and the checksum  
A
P
I
Frame-specific Data Frame Type  
Frame ID  
Identifies the serial port data frame for the host to  
correlate with a subsequent ACK (acknowledgement). If  
set to 0, no response is sent.  
4 0x52 (R)  
P
a
c
k
e
t
AT Command  
5 0x4E (N)  
6 0x4A (J)  
Command Name - Two ASCII characters that identify the  
AT Command.  
If present, indicates the requested parameter  
value to set the given register.  
If no characters present, register is queried.  
Parameter Value  
(optional)  
Checksum  
7
0x0D  
0xFF - the 8 bit sum of bytes from offset 3 to this byte.  
The above example illustrates an AT command when querying an NJ value.  
AT Command - Queue Parameter Value  
Frame Type: 0x09  
This API type allows module parameters to be queried or set. In contrast to the “AT Command” API type, new  
parameter values are queued and not applied until either the “AT Command” (0x08) API type or the AC (Apply  
Changes) command is issued. Register queries (reading parameter values) are returned immediately.  
Example: Send a command to change the baud rate (BD) to 115200 baud, but don't apply  
changes yet. (Module will continue to operate at the previous baud rate until changes are applied.)  
Frame Fields  
Offset Example  
0 0x7E  
Description  
Start Delimiter  
Length  
MSB 1 0x00  
LSB 2 0x05  
3 0x09  
Number of bytes between the length and the checksum  
A
P
I
Frame-specific Data Frame Type  
Frame ID  
Identifies the serial port data frame for the host to  
correlate with a subsequent ACK (acknowledgement). If  
set to 0, no response is sent.  
4 0x01  
P
a
c
k
e
t
5 0x42 (B)  
6 0x44 (D)  
Command Name - Two ASCII characters that identify the  
AT Command.  
AT Command  
If present, indicates the requested parameter  
value to set the given register.  
If no characters present, register is queried.  
Parameter Value  
(ATBD7 = 115200  
baud)  
7 0x07  
8 0x68  
Checksum  
0xFF - the 8 bit sum of bytes from offset 3 to this byte.  
Note: In this example, the parameter could have been sent as a zero-padded 2-byte or 4-byte value.  
ZigBee Transmit Request  
Frame Type: 0x10  
A Transmit Request API frame causes the module to send data as an RF packet to the specified destination.  
The 64-bit destination address should be set to 0x000000000000FFFF for a broadcast transmission (to all  
devices). The coordinator can be addressed by either setting the 64-bit address to all 0x00s and the 16-bit  
address to 0xFFFE, OR by setting the 64-bit address to the coordinator's 64-bit address and the 16-bit address  
to 0x0000. For all other transmissions, setting the 16-bit address to the correct 16-bit address can help improve  
performance when transmitting to multiple destinations. If a 16-bit address is not known, this field should be  
set to 0xFFFE (unknown). The Transmit Status frame (0x8B) will indicate the discovered 16-bit address, if  
successful.  
© 2010 Digi International, Inc.  
101  