NVFM
Operation condition
Insulation Resistance
1)
Dielectric Strength
1)
Between contacts
Between contact and coil
100M
min (at 500VDC)
Item 7 of IEC255-5
Item 6
Item 6
of IEC255-5
of IEC255-5
50Hz 500V
50Hz 1000V
Shock resistance
100m/s
2
11ms
IEC68-2-27 Test Ea
Vibration resistance
10~40Hz double amplitude 1.27mm IEC68-2-6 Test Fc
8N 4N PC type
Terminals strength
IEC68-2-21 Test Ua1
235x2 3x0.5s
Solderability
IEC68-2-20 Test Ta method 1
-40~85
Ambient Temperature
85% (at 40)
Relative Humidity
IEC68-2-3 Test Ca
Mass
18.5g
Note: 1). ,When testing, coil terminals shall be connect , if coil transient suppression is installed in relay .
Qualification inspection:
Perform the qualification test as specified in the table
of IEC255-19-1 and minimum sample size 24.
Dimensions (Unit: mm)
>àçÇá
nãîÜ>àç>ìòèÑ
Mounting (Bottom views)
na`>>ìòèÑ
Note: Footprint as shown above
is also available.
Dimensions
Wiring diagram (Bottom views)
mm
0.8
1.4
2.1
2.4
2.5
2.7
3.2
4.5
4.8
5.5
6.3
6.4
8
9
9.5
11.5
14
15
15.5
23
26
0.031
0.055
0.083
0.094
0.098
0.106
0.126
0.177
0.189
0.127
0.248
0.252
0.315
0.354
0.374
0.453
0.551
0.591
0.610
0.905
1.024
NOTES
1).Dimensions are in millimeter.
2).Inch equivalents are given for general information only.
Reference Data
www.dblectro.com