欢迎访问ic37.com |
会员登录 免费注册
发布采购

N68F 参数 Datasheet PDF下载

N68F图片预览
型号: N68F
PDF下载: 下载PDF文件 查看货源
内容描述: 的合适的塑料材料就业要施加到高温和各种化学溶液 [Employment of suitable plastic materials to be applied to high temperature and various chemical solution]
分类和应用:
文件页数/大小: 3 页 / 453 K
品牌: DBLECTRO [ DB LECTRO INC ]
 浏览型号N68F的Datasheet PDF文件第1页浏览型号N68F的Datasheet PDF文件第3页  
NHG RELAYS
N68F
R
C
28.5 10.1 12.3
E158859
Patent NO.:03209705.0
US
Features
Slim type and small occupying area can offer high density P.C.B. technique.
Employment of suitable plastic materials to be applied to high temperature and various chemical solution.
Dielectric strength 5000V.
Creepage distance >8mm.
Ordering Information
N68F C S 8 C DC12V F
1
2
3
4
5
6
7
5 Contact material NIL:AgNi (Gold clad) W:AgNi
CD:AgCdO (Gold clad) C:AgCdO
6 Coil rated voltage(V) DC:5,6,12,18,24,48,60
7 Resist heat class B:130
F:155
1C (SPDT(B-M))
8A/250VAC
300W
30VDC
2500VA
Max. Switching Current:10A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
1 Part number N68F
2 Contact arrangement A:1A;C:1C
3 Enclosure S:Sealed type Z:Dust cover
4 Contact current 8A
Contact Data
Contact Arrangement
Contact Material
Contact Rating
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operational
life
Electrical
Mechanical
1A (SPSTNO
Resistive
Resistive
125VDC 380VAC
100m
10
10
7
5
Ag CdO Ag SnO
2
Coil Parameter
Dash
numbers
Coil voltage
VDC
Rated
005-220
006-220
012-220
018-220
024-220
048-250
003-250
5
6
12
18
24
48
60
Max
11.8
14.1
28.2
42.3
56.4
112.8
141.0
113
164
620
1295
2350
9600
12500
Coil
resistance
10%
Pickup
voltage
VDC (max)
(75%of rated
voltage )
3.75
4.5
9.0
13.5
18.0
36.0
45.0
Release
voltage
VDC (min)
(10% of
rated
voltage)
0.5
0.6
1.2
1.8
2.4
4.8
6.0
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
0.22
7
3
0.25
7
3
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
3.Unless otherwise stated, the rated coil voltage specified in coil parameter table shall be used for all tests and its
application to the relay.