NHG RELAYS
JZX-18FF
03001003515
R
28
21.5
35
R2133923
C
US
E158859
Features
Small size, light weight, heavy reverse power.
Optional mounting ways.
Firm structure, strong anti-shock & anti vibration.
Suitable for automatic control, telecommunication equipment, household electrical appliances and machinery electrical
facilities.
Ordering Information
JZX-18FF 2C a DC12V 1 L
1
2
3
4
5
6
5 Cover 1:1Mode 2:2 Mode
6 Coil transient suppression L:with LED
D:with diode;
LD:with LED & diode
NIL:standard
1 Part number JZX-18FF
2 Contact arrangement 2A:2A 2B:2B 2C:2C
3A:3A 3B:3B 3C:3C 4C:4C
3 Terminal a: inserting type b: PCB type
4 Coil rated Voltage(V) AC:6,12,24,36,48,110,120,220
DC:6,12,24,36,48,110
Contact Data
Contact Arrangement
Contact Material
Contact Rating
(resistive)
Max. Switching Power
Max. Switching Voltage
Max. Resistance or
Voltage drop
Operation
al Electrical
life
Mechanical
2A (DPSTNO) 2B (DPSTNC) 2C (DPDT (B-M)
3A (3PSTNO) 3B (3PSTNC) 3C (3PDT (B-M)
4C (4PDT(B-M))
Ag CdO Silver Alloy
2A,2B,2C&3A,3B,3C:5A/220VAC,28VDC; Heavy load:7A/220VAC,28VDC
4C:3A/220VAC,28VDC; Heavy load:5A/220VAC,28VDC
1250W
2500VA
150VDC 380VAC
Max.Switching Current:7A
50m
3A:5 10
5
5A:2 10
5
7A:1 10
5
2 10
7
Heavy load:1 10
7
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
Coil Parameter
Dash
numbers
Coil voltage
V
Rated
AC
006AC
012AC
024AC
036AC
048AC
110AC
120AC
220AC
6
12
24
36
48
110
120
220
DC
006-900
012-900
024-900
036-900
048-900
110-900
6
12
24
36
48
110
6.6
13.2
26.4
39.6
52.8
121
40
160
640/650
1500
2600
11000
150
75
36.9
24.5
18.5
10.0
4.8
9.6
19.2
28.8
38.4
88.0
6.6
13.2
26.4
39.6
52.8
121
132
242
11.5
46
184
370
735
3750
4550
14400
183.0
91.0
46.0
33.0
24.0
11.0
9.8
4.2
Max.
Coil
resistance
10%
Rated
current
mA
Pick up
Release
voltage
voltage
V(max)
V(min)
(80%of rated (30%of rated
Voltage)
voltage)
4.8
9.6
19.2
28.8
38.4
88.0
96.0
176
1.8
3.6
7.2
10.8
14.4
33.0
36.0
66.0
10%of rated
voltage
0.6
1.2
2.4
3.6
4.8
11.0
Coil
power
Operate
Time
ms
Release
Time
ms
1.2VA
25
25
0.9W
25
25
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.