欢迎访问ic37.com |
会员登录 免费注册
发布采购

JZC-33FCS10DC12V0.45 参数 Datasheet PDF下载

JZC-33FCS10DC12V0.45图片预览
型号: JZC-33FCS10DC12V0.45
PDF下载: 下载PDF文件 查看货源
内容描述: 密封和非密封可用的类型 [Sealed & Unsealed types available]
分类和应用:
文件页数/大小: 3 页 / 356 K
品牌: DBLECTRO [ DB LECTRO INC ]
 浏览型号JZC-33FCS10DC12V0.45的Datasheet PDF文件第1页浏览型号JZC-33FCS10DC12V0.45的Datasheet PDF文件第3页  
NHG RELAYS
JZC-33F
03001003510
R
20.5 10.6 15.6
R50016343
C
US
E160644
Features
5A 10A switching capabilities.
Subminiature,standard PC layout.
Sealed & Unsealed types available.
Ordering Information
JZC-33F C S 10 DC12V 0.45
1
2
3
4
5
6
4 Contact current 3A,5A,10A
5 Coil rated voltage(V) DC:3,5,6,9,12,18,24
6 Coil power consumption 0.2:0.2W 0.45:0.45W
1 Part number JZC-33F
2 Contact arrangement A:1A C:1C
3 Enclosure S:Sealed type Z:Dust cover
Contact Data
Contact Arrangement
Contact Material
Contact Rating(resistive)
1A (SPSTNO) 1C (SPDT (B-M))
Ag Silver Alloy
1A:5A/250VAC,30VDC;10A/125VAC
1C:NO:5A/250VAC,30VDC;10A/125VAC
NC:3A,5A/250VAC,30VDC
Motor load:1/4HP 250VAC
Lamp load:TV-5
150W 1250VA
30VDC 277VAC
100m
10
5
10
7
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation
al
life
Electrical
Mechanical
Max.Switching Current:10A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
(1A/24VDC)
Coil Parameter
Dash
numbers
Rated
voltage
VDC
Rated
003-200
005-200
006-200
009-200
012-200
018-200
024-200
003-450
005-450
006-450
009-450
012-450
018-450
024-450
3
5
6
9
12
18
24
3
5
6
9
12
18
24
Max.
3.3
5.5
6.6
9.9
13.2
19.8
26.4
3.3
5.5
6.6
9.9
13.2
19.8
26.4
45
125
180
405
720
1620
2880
20
56
80
180
320
720
1280
Coil
resistance
10%
Pickup
voltage
V(max)
75%of rated
Volt
2.25
3.75
4.50
6.75
9.00
13.5
18.0
2.25
3.75
4.50
6.75
9.00
13.5
18.0
Release
voltage
VDC(min)
5%of rated
Volt
0.15
0.25
0.30
0.45
0.60
0.90
1.20
0.15
0.25
0.30
0.45
0.60
0.90
1.20
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
0.20
8
5
0.45
8
5
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.