NHG RELAYS
JQX- 62F
03001003505
R
R50007462
29 12.6 24.5
C
US
E158859
Features
Can be welded directly onto PCB.
Used in household appliances like air conditioning , heater and instruments etc.
Ordering Information
JQX-62F A Z
1
2
3
1 Part number JQX-62F
2 Contact arrangement A:1A
3 Enclosure Z: Dust cover
20 C DC12V
4
5
6
4 Contact rating 20A/125VAC 16A/250VAC 24VDC
5 Contact material C:AgCdO NIL:AgSnO
2
6 Coil rated voltage(V) DC:5,6,9,12,18,24,48
Contact Data
Contact Arrangement
Contact Material
Contact Rating resistive
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation life
Electrical
Mechanical
1A SPSTNO
AgSnO
2
AgCd
20A/125VAC 16A/250VAC 24VDC
385W 4000VA
Min. Switching Current 10mA/5V
30VDC 277VAC
Max. Switching Current:20A
50m
Item 3.12 of IEC255-7
10
5
Item 3.30 of IEC255-7
7
10
Item 3.31 of IEC255-7
CAUTION:
Relays previously tested or used above 10mA resistive at 6VDC maximum or peak AC open circuit are not recommended
for subsequent use in law level applications.
Coil Parameter
Dash
numbers
Coil voltage
VDC
Rated
Max.
Coil
current
mA
Pickup
voltage
Coil
resistance VDC(max)
10% (80%of rated
voltage )
46
67
150
270
600
1100
4267
3.75
4.50
6.75
9.00
13.5
18.0
36.0
Release
voltage
VDC(min)
(10% of
rated
voltage)
0.25
0.30
0.45
0.60
0.90
1.20
2.40
Coil power
consumption
W
Operate Release
Time
Time
ms
ms
005-540
006-540
009-540
012-540
018-540
024-540
048-540
5
6
9
12
18
24
48
6.5
7.8
11.7
15.6
23.4
31.2
62.4
108
90
60
44.4
30
21.8
11.3
0.54
20
10
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.