欢迎访问ic37.com |
会员登录 免费注册
发布采购

FUSB185 参数 Datasheet PDF下载

FUSB185图片预览
型号: FUSB185
PDF下载: 下载PDF文件 查看货源
内容描述: 径向引线PTC FUSB系列 [Radial Leaded PTC FUSB Series]
分类和应用:
文件页数/大小: 3 页 / 112 K
品牌: DBLECTRO [ DB LECTRO INC ]
 浏览型号FUSB185的Datasheet PDF文件第2页浏览型号FUSB185的Datasheet PDF文件第3页  
Radial Leaded PTC FUSB Series
FUZETEC
Application:
Low voltage USB equipment
Product Features:
Low resistance, Fast trip time , Lower
Trip-to-hold Ratio
Operation Current:
750mA ~2.5A
Maximum Voltage:
16V/30V
Temperature Range:
-40
to 85
Agency Approvals:
UL(E211981),
C-UL(E211981),
TUV (R3-50004084)
Electrical characteristics(23 )
Part
Number
FUSB075
FUSB090
FUSB110
FUSB120
FUSB135
FUSB155
FUSB160
FUSB185
FUSB250
Hold
Trip
Current Current
Max.Time
to Trip
at 8A at 5xI
H
0.4
--
1.2
5.9
2.3
6.6
0.5
--
4.5
7.3
0.6
--
9.0
8.0
10.0
8.7
40.0 10.3
Maximum
Current
I
MAX
,A
40
40
40
40
40
40
40
40
40
Resistance
Rated Typical
Tolerance
Voltage Power
R
MIN
R
1
MAX
V
MAX
,V
dc
Pd, W
16/30
0.3
16/30
0.6
16/30
0.7
16/30
0.6
16/30
0.8
16/30
0.7
16/30
0.9
16/30
1.0
16/30
1.2
0.080
0.070
0.050
0.040
0.040
0.030
0.030
0.030
0.020
0.23
0.18
0.14
0.14
0.12
0.12
0.11
0.09
0.07
I
H
,
A
0.75
0.90
1.10
1.20
1.35
1.55
1.60
1.85
2.50
I
T
,
A
1.30
1.80
2.20
2.00
2.70
2.70
3.20
3.70
5.00
I
H
=Hold current-maximum current at which the device will not trip at 23 still air.
I
T
=Trip current-minimum current at which the device will always trip at 23 still air.
V
MAX
=Maximum voltage device can withstand without damage at its rated current.
I
MAX
= Maximum fault current device can withstand without damage at rated voltage (V max).
Pd=Typical power dissipated from device when in the tripped state in 23 still air environment.
R
MIN
=Minimum device resistance at 23 .
R
1
MAX
=Maximum device resistance at 23 , 1 hour after tripping .
Physical specifications:
Lead material: Tin plated copper,24 AWG.
Soldering characteristics: Soldering ability per ANSI/J-STD 002
Solder heat withstand per IEC 68-2-20
FUSB 120 :Test Tb, method 1a, condition a; can withstand 5 second at 260
All others: Test Tb, method 1a, condition a; can withstand 10 second at 260
Insulating coating:Flame retardant epoxy polymer ,meets UL 94V-O requirement.
5
5
1
DB LECTRO Inc., 3600-I, boulevard Matte, Brossard, QC J4Y 2Z2