PASSIVE DELAY LINE TEST SPECIFICATIONS
TEST CONDITIONS
INPUT:
OUTPUT:
Ambient Temperature:
Source Amplitude:
Source Impedance:
Input Frequency:
25oC ± 3oC
0dBm typical
50W nominal
27.777778MHz
Zload
:
50W nominal
Network analyzer is used in phase measurement mode, normalized with a wire jumper between input and
output of DUT test socket. Delay is related to phase lag with proportionality constant of 100ps/deg.
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
50-OHM
RF
OUT
IN R
IN A
IN
SIGNAL
DIVIDER
(HP 35676
-66301)
50-Ohm Coax
50-Ohm Coax
OUT R
OUT A
OUT B
50-Ohm Coax
IN
GND
NETWORK
ANALYZER
(HP 3577A)
DEVICE UNDER
TEST (DUT)
IN B
50-Ohm Coax
OUT
GND
Test Setup
Doc #01009
10/31/01
DATA DELAY DEVICES, INC.
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com