DS1305  
Figure 2. RTC REGISTERS AND ADDRESS MAP  
HEX ADDRESS  
Bit7 Bit6  
Bit5  
Bit4  
Bit3 Bit2  
Bit1  
Bit0  
RANGE  
READ  
00H  
WRITE  
80H  
0
0
10 Seconds  
10 Minutes  
P
Seconds  
00–59  
00–59  
01H  
81H  
Minutes  
01–12 + P/A  
12  
02H  
82H  
0
10 Hour  
Hours  
A
10  
0
00–23  
24  
03H  
04H  
05H  
06H  
83H  
84H  
85H  
86H  
0
0
0
0
0
0
0
Day  
Date  
1–7  
1–31  
01–12  
00–99  
10 Date  
10 Month  
10 Year  
Month  
Year  
Alarm 0  
07H  
87H  
M
M
10 Seconds Alarm  
10 Minutes Alarm  
P
Seconds Alarm  
Minutes Alarm  
00–59  
08H  
88H  
00–59  
12  
01–12 + P/A  
09H  
89H  
M
M
10 Hour  
Hour Alarm  
Day Alarm  
A
10  
0
24  
0
00–23  
01–07  
0AH  
8AH  
0
Alarm 1  
0BH  
8BH  
M
M
10 Seconds Alarm  
10 Minutes Alarm  
P
Seconds Alarm  
Minutes Alarm  
00–59  
0CH  
8CH  
00–59  
12  
01–12 + P/A  
0DH  
8DH  
M
M
10 Hour  
Hour Alarm  
Day Alarm  
A
10  
0
24  
0
00–23  
01–07  
0EH  
0FH  
8EH  
8FH  
0
Control Register  
Status Register  
10H  
90H  
11H  
91H  
Trickle Charger Register  
Reserved  
12–1FH  
20–7FH  
92–9FH  
A0–FFH  
96 Bytes User RAM  
00–FF  
Note: Range for alarm registers does not include mask’m’ bits.  
The DS1305 can be run in either 12-hour or 24-hour mode. Bit 6 of the hours register is defined as the  
12- or 24-hour mode select bit. When high, the 12-hour mode is selected. In the 12-hour mode, bit 5 is the  
AM/PM bit with logic high being PM. In the 24-hour mode, bit 5 is the second 10-hour bit (20 to 23  
hours).  
The DS1305 contains two time-of-day alarms. Time-of-day Alarm 0 can be set by writing to registers 87h  
to 8Ah. Time-of-day Alarm 1 can be set by writing to registers 8Bh to 8Eh. The alarms can be  
programmed (by the INTCN bit of the control register) to operate in two different modes; each alarm can  
drive its own separate interrupt output or both alarms can drive a common interrupt output. Bit 7 of each  
of the time-of-day alarm registers are mask bits (Table 1). When all of the mask bits are logic 0, a time-  
of-day alarm only occurs once per week when the values stored in timekeeping registers 00h to 03h  
match the values stored in the time-of-day alarm registers. An alarm is generated every day when bit 7 of  
the day alarm register is set to a logic 1. An alarm is generated every hour when bit 7 of the day and hour  
alarm registers is set to a logic 1. Similarly, an alarm is generated every minute when bit 7 of the day,  
hour, and minute alarm registers is set to a logic 1. When bit 7 of the day, hour, minute, and seconds  
alarm registers is set to a logic 1, alarm occurs every second.  
6 of 21  