DS1040  
tRISE (Input Rise Time): The elapsed time between the 20% and the 80% point on the leading edge of  
the input pulse.  
tFALL (Input Fall Time): The elapsed time between the 80% and the 20% point on the trailing edge of  
the input pulse.  
tD (Intrinsic Delay): The elapsed time between the 1.5 point on the leading edge of the input trigger  
pulse and the 1.5V point on the leading edge of output pulse.  
tPU (Power-up Time): After VCC is valid, the time required before timing specifications is within  
tolerance.  
TEST SETUP DESCRIPTION  
Figure 4 illustrates the hardware configuration used for measuring the timing parameters on the DS1040.  
The input waveform is produced by a precision pulse generator under software control. The intrinsic  
delay is measured by a time interval counter (20 ps resolution) connected between the input and each  
output. Outputs are selected and connected to the counter by a VHF switch control unit. Width  
measurements are made by directing both the start and stop functions of the counter to the same output.  
All measurements are fully automated, with each instrument controlled by a central computer over an  
IEEE 488 bus.  
TEST CONDITIONS  
Input:  
Ambient Temperature:  
Supply Voltage (VCC):  
Input Pulse:  
25°C + 3°C  
5.0V + 0.1V  
High = 3.0V + 0.1V  
Low = 0.0V + 0.1  
Source Impedance:  
Rise and Fall Time:  
50 ohm max.  
3.0 ns max. (measured  
between 0.6V and 2.4)  
Pulse Width:  
Period:  
500 ns (1 µs for -500)  
1 µs (2 µs for -500)  
Output:  
The output is loaded with a 74F04. Delay is measured at the 1.5V level on the rising and falling edge.  
Note:  
Above conditions are for test only and do not restrict the operation of the device under other data sheet  
conditions.  
6 of 6