ES51932  
22,000 Counts Auto DMM  
3.6 Relative + Max/Min + HOLD  
Max/Min mode can be nested in REL mode. The meter displays the maximum or  
minimum value relative to the reference when Max/Min is pressed in REL mode.  
Pressing HOLD under REL + Max/Min makes the meter stop updating the LCD panel.  
Original State  
(Auto/Manual)  
Push REL  
Push REL  
RELactive.  
The relative value  
Push Max/Min > 1s  
Push Max/Min  
RELandMaxactive.  
RELandMinactive.  
RELMaxMin〞  
Maximum rel. value  
Minimum rel. value  
blink. Current rel. value  
Push Max/Min  
Push Max/Min  
Push HOLD  
Push HOLD  
Push HOLD  
REL,Max,  
Hactive. Hold  
max. rel. value  
REL, Min,  
Hactive. Hold  
REL, Max, Min,  
Hblink. Hold the  
current rel. value  
Push Max/Min  
Push Max/Min  
min. rel. value  
Push Max/Min  
3.7 Zero : In manual DC 22.000A, 220.00A, 2200.0A and 22000A measurement  
modes, the REL pin changes to control Zero function instead of relative function. In  
Zero mode, the LCD panel displays DN+K - DN, where DN = 1, 2, 3, , DN is the last  
conversion value before Zero is pushed, and DN+K is the current conversion value. If  
Zero is pushed again in Zero mode, the meter will refresh the DN value and displays the  
DN+K - DN again. The meter returns to normal operation if Zero is pressed and held for  
longer than one second. Pressing HOLD in Zero mode makes the meter stop updating  
the LCD panel. In Zero mode, LCD will not show any symbol to remind users of Zero  
mode is active. In 2-range auto DCA modes for clampmeter (220.00A/2200.0A or  
22.000A/220.00A), the system will stay in automatic mode, even if the Zero function is  
activated. In other words, it could achieve real automatic operation. In automatic mode,  
Zero function could not be entered from higher range, but it could be still activated if  
current range is lower one. This is because most residual current value is so small that  