ES51945(5000counts)
Dual Display/No Cap
2.11 Auto power off (APO) and idle time selection
ES51945 has a default auto power off function. If the meter is idle for more than the given
Idle Time, the chip automatically turns the power off. The idle time to trigger the auto
power off function is determined by pin ‘APOSEL’. If pin APOSEL is connected to V-, the
Idle Time will be set to 30 minutes. If pin APOSEL is connected to DGND or floating, the
Idle Time will be set to 15 minutes. When APO happens, the state of the meter is saved. The
APO sign on the LCD panel indicates whether the auto power off is enabled or not. If user
might want to disable Auto power off, power on the meter when any of the push functions,
except for HOLD, is pressed down.
Note:
1. Powering on the meter while pressing HOLD and lasts 2 seconds turns on all LCD segments until HOLD
is pressed again.
2. When low battery status happened (LCD show “Lo.bt”), the APO idle time will be reset to 60 sec.
2.12 Sleep
The meter enters sleep mode after auto power off. The SLEEP pin asserts low (V-) in the
sleep mode, and asserts high (V+, not 0V) after re-power on.
2.13 Re-power on
After auto power-off, pushing any of the push function or changing the rotary mode can
turn on the meter again. If the meter is re-powered on by changing the rotary mode, the
saved state is cleared. If the meter is re-powered on by push functions, the chip restores the
saved state and enters HOLD mode. The LCD displays the saved value.