ES51927
6000 Counts Smart DMM
1.3 Resistance Measurement
A re-configurable divider automatically provides a suitable full-scale range in
resistance measurement mode. The following table summarizes the full-scale
ranges and the reference resistors in each configuration.
Configuration
OR1
Full Scale Range
600.0Ω*
Relative Resistor
OR1
Equivalent value
100Ω
OR2
6.000KΩ
VR5
1KΩ
OR3
60.00KΩ
VR4
10KΩ
OR4
600.0KΩ
100KΩ
VR3∥VR1
OR5
OR6
6.000MΩ
60.00MΩ**
1MΩ
10MΩ
VR2∥VR1
VR1
Note: * When auto scan mode is set, continuity check is implemented in this range
** When auto scan mode is set, the 60.00MΩ range is omitted
1.3.1 Continuity check
Continuity check shares the same configuration with 600.0Ω manual resistance
measurement mode and has buzzer output to indicate continuity. The buzzer
generates 2KHz beep whenever the reading is less than 30Ω.
1.4 Diode Measurement
Diode measurement mode shares the same configuration with 6.000V manual
voltage measurement mode and has buzzer output to indicate continuity. The
buzzer generates a 2KHz sound whenever the reading is less than 30mV. If the
test circuit is open or the voltage drop between the two ports of the device (diode)
under test is larger than 2V, the LCD panel will show “OL”.
Ver 2.9
9