ES51981
3 1/2 AUTO DMM
When FC5 is LOW, KEY is disable. The corresponding measurement modes are list
below
SLACDC FC1 FC2 FC3 FC4
Mode
0
0
0
0
0
1
1
1
1
1
1
1
1
0
1
1
1
1
0
0
0
0
0
0
0
1
1
0
0
0
1
1
0
0
0
1
0
1
1
1
0
1
0
0
1
0
1
0
0
1
0
0
1
0
1
1
1
1
0
1
1
1
1
0
1
1
1
1
0
AC Voltage Measurement
AC Current Measurement(µA)
AC Current Measurement(mA)
Manual AC Current Measurement(A)
Auto AC Current Measurement(A)
DC Voltage Measurement
DC Current Measurement(µA)
DC Current Measurement(mA)
Manual DC Current Measurement(A)
Auto DC Current Measurement(A)
Resistance Measurement
1
X
X
X
X
X
Resistance Measurement
Continuity Check
diode Measurement
Temperature(℉)
Ps. X means “don’t care”
The other combinations of FC1, FC2, FC3, and FC4 are for ADP modes. In ADP modes
, if FC5 is LOW, the minus sign on the LCD panel will not be displayed. And if KEY pin
is floating, the buzzer beeps when the input signal is overflow. The ADP mode function is
summarized below.
FC1 FC2 FC3 FC4
Mode
ADP0
ADP1
ADP2
ADP3
1
1
1
1
1
1
0
0
1
0
0
1
0
0
0
0
Note: Temperature measurement mode takes input signal from ADP pin. In temperature
measurement mode, VBAR pin is used to control the right most digit point on the
LCD panel. When VBAR is LOW, this digit point is displayed.
3. Push function
3.1 HOLD
HOLD mode makes the meter stop updating the LCD panel. This mode can be nested in
most of the special modes. Enabling HOLD function in automatic mode makes the
meter switch to manual mode, but the full scale range remains the same. HOLD function
can be cancelled by changing the measurement mode, pressing RANGE, or push HOLD
again.
10
08/09/09