ES51960
3 3/4 Auto DMM
(2) Switch Description
Rotary mode : FC1,FC2,FC3,FC4,FC5
Measurement mode depends on the logic levels of FC1,FC2,FC3,FC4
FC5 and KEY :
When FC5=1
FC1 FC2 FC3 FC4 Mode
Push mode(KEY)
DC V — AC V
1
1
1
1
0
1
1
1
1
1
0
1
0
1
1
0
0
1
1
1
DC V
DC uA
DC mA
DC A
DC uA — AC uA
DC mA — AC mA
DC A — AC A
Ω
Ω— Continuity
0
1
1
0
Continuity
Ω
Continuity — Diode
1
0
1
1
Ω— Continuity — Diode
1
0
1
0
Frequency
When FC5=0, KEY is disabled.
FC1 FC2 FC3 FC4 Mode
1
1
1
1
0
0
1
1
1
1
1
1
1
1
0
0
0
1
0
1
1
1
1
1
0
0
1
1
1
0
1
0
ACV
AC uA
AC mA
ACA
Ω
Continuity
Diode
Frequency
Under ADP mode
(1) FC5=1, when the input value is overflow, the buzzer will beep.
(2) FC5=0, when the input value is overflow, the buzzer will not beep.
FC1 FC2 FC3 FC4 Mode
0
1
0
0
0
1
0
0
1
0
0
0
1
0
0
0
0
0
1
0
0
0
1
0
1
1
1
1
0
0
0
0
ADP0
ADP1
ADP2
ADP3
ADP0(no bar)
ADP1(no bar)
ADP2(no bar)
ADP3(no bar)
10
92年8月4日