CY7C419/21/25/29/33
Operating Range
Range
Commercial
Industrial
Military
Ambient Temperature
[2]
0
°
C to + 70
°
C
–40
°
C to +85
°
C
–55
°
C to +125
°
C
V
CC
5V
±
10%
5V
±
10%
5V
±
10%
Electrical Characteristics
Over the Operating Range
[3]
7C419–10, 15, 30, 40
7C420/1–10, 15, 20, 25, 30, 40, 65
7C424/5–10, 15, 20, 25, 30, 40, 65
7C428/9–10, 15, 20, 25, 30, 40, 65
7C432/3–10, 15, 20, 25, 30, 40, 65
Parameter
Description
V
OH
Output HIGH Voltage
V
OL
V
IH
V
IL
I
IX
I
OZ
I
OS
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Input Leakage Current
Output Leakage Current
Output Short Circuit Current
[5]
GND < V
I
< V
CC
R > V
IH
, GND < V
O
< V
CC
V
CC
= Max., V
OUT
= GND
Test Conditions
V
CC
= Min., I
OH
= –2.0 mA
V
CC
= Min., I
OL
= 8.0 mA
Com’l
Mil/Ind
Min.
2.4
2.0
2.2
Note 4
–10
–10
Max.
0.4
V
CC
V
CC
0.8
+10
+10
–90
Unit
V
V
V
V
µA
µA
mA
Electrical Characteristics
Over the Operating Range
[3]
(continued)
7C419–10
7C421–10
7C425–10
7C429–10
7C433–10
Parameter
I
CC
Description
Operating Current
Test Conditions
V
CC
= Max.,
I
OUT
= 0 mA
f = f
MAX
V
CC
= Max.,
I
OUT
= 0 mA
F = 20 MHz
All Inputs =
V
IH
Min.
Com’l
Mil/Ind
Com’l
35
85
7C419–15
7C421–15
7C425–15
7C429–15
7C433–15
65
100
35
7C420–20
7C421–20
7C424–20
7C425–20
7C428–20
7C429–20
7C433–20
55
90
35
7C420–25
7C421–25
7C424–25
7C425–25
7C429–25
7C432–25
7C433–25
Unit
mA
50
80
35
mA
Min. Max. Min. Max. Min. Max. Min. Max.
I
CC1
Operating Current
I
SB1
I
SB2
Standby Current
Com’l
Mil/Ind
Com’l
Mil/Ind
10
5
10
15
5
8
10
15
5
8
10
15
5
8
mA
mA
Power-Down Current All Inputs >
V
CC
–0.2V
Notes:
2. T
A
is the “instant on” case temperature.
3. See the last page of this specification for Group A subgroup testing information.
4. V
IL
(Min.) = –2.0V for pulse durations of less than 20 ns.
5. For test purposes, not more than one output at a time should be shorted. Short circuit test duration should not exceed 30 seconds.
Document #: 38-06001 Rev. *A