CY62128V Family
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65°C to +150°C
Ambient Temperature with
Power Applied ............................................. –55°C to +125°C
Supply Voltage to Ground Potential
(Pin 28 to Pin 14) ........................................... –0.5V to +4.6V
DC Voltage Applied to Outputs
in High Z State
[1]
....................................–0.5V to V
CC
+ 0.5V
DC Input Voltage
[1]
.................................–0.5V to V
CC
+ 0.5V
Output Current into Outputs (LOW)............................. 20 mA
Static Discharge Voltage .......................................... >2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current .................................................... >200 mA
Operating Range
Range
Commercial
Industrial
Ambient Temperature
0°C to +70°C
–40°C to +85°C
V
CC
1.6V to 3.6V
1.6V to 3.6V
Product Portfolio
Power Dissipation (Commercial)
V
CC
Range
Product
CY62128V
CY62128V25
CY62128V18
Min.
2.7V
2.3V
1.6V
Typ.
[2]
3.0V
2.5V
1.8V
Max.
3.6V
2.7V
2.0V
Speed
55, 70 ns
100 ns
200 ns
Operating (I
CC
)
Typ.
[2]
20 mA
15 mA
10 mA
Maximum
40 mA
20 mA
15 mA
Typ.
[2]
0.4
µA
0.3
µA
0.3
µA
Standby (I
SB2
)
Maximum
100
µA
(XL = 10
µA)
50
µA
(LL = 12
µA)
30
µA
(LL = 10
µA)
Electrical Characteristics
Over the Operating Range
CY62128V-55/70
Parameter
V
OH
V
OL
V
IH
V
IL
I
IX
I
OZ
I
CC
Description
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Input Load Current
Output Leakage Current
V
CC
Operating Supply
Current
GND < V
I
< V
CC
GND < V
O
< V
CC
, Output Disabled
V
CC
= Max.,
I
OUT
= 0 mA,
f = f
MAX
= 1/t
RC
Com’l,
70 ns
Ind’l,
55 ns
Ind’l,
70 ns
I
SB1
Automatic CE
Power-Down Current—
TTL Inputs
Max. V
CC
, CE > V
IH
,
V
IN
> V
IH
or
V
IN
< V
IL
, f = f
MAX
Com’l,
70 ns
Coml,
55 ns
Ind’l
L
LL, XL
LL
L
LL
L
LL, XL
LL
L
LL
Test Conditions
V
CC
= Min., I
OH
= –1.0 mA
V
CC
= Min., I
OL
= 2.1 mA
Min.
2.4
0.4
2
–0.5
–1
–1
±1
±1
20
20
23
20
20
15
15
17
15
15
V
CC
+0.5V
0.8
+1
+1
40
40
50
40
40
300
300
350
300
300
µA
Typ.
[2]
Max.
Unit
V
V
V
V
µA
µA
mA
Notes:
1. V
IL
(min.) = –2.0V for pulse durations of less than 20 ns.
2. Typical values are included for reference only and are not guaranteed or tested. Typical values are measured at V
CC
= V
CC
Typ., T
A
= 25°C.