BCM89359 Advance Data Sheet
Recommended Operating Conditions and DC Characteristics
Table 27: Recommended Operating Conditions and DC Characteristics (Cont.)
Value
Parameter
Input low voltage
Symbol
Minimum Typical Maximum Unit
VIL
–
–
–
–
0.35 ×
VDDIO
V
V
V
Output high voltage @ 2 mA
VOH
VOL
VDDIO –
0.45
–
Output low voltage @ 2 mA
–
0.45
RF Switch Control Output Pinsc
For VDDIO_RF = 3.3V:
Output high voltage @ 2 mA
VOH
VOL
VDDIO –
0.4
–
–
V
Output low voltage @ 2 mA
Input capacitance
–
–
–
–
0.40
5
V
C
pF
IN
a. The BCM89359 is functional across this range of voltages. Optimal RF performance specified in the data sheet,
however, is guaranteed only for 3.2V < VBAT < 4.8V.
b. The maximum continuous voltage is 5.25V. Voltage transients up to 6.0V for up to 10 seconds, cumulative
duration over the lifetime of the device, are allowed. Voltage transients as high as 5.5V for up to 250 seconds,
cumulative duration over the lifetime of the device, are allowed.
c. Programmable 2 mA to 16 mA drive strength. Default is 10 mA.
Broadcom®
September 9, 2014 • 89359-DS100-R
Page 94
BROADCOM CONFIDENTIAL