CYW43362
a. The cellular standards listed indicate only typical usages of that band in some countries. Other standards may also be used within those bands.
b. Derate by 1.5 dB for temperatures less than –10°C or more than 55°C, or voltages less than 3.0V. Derate by 3.0 dB for voltages of less than
2.7V or voltages of less than 3.0V at temperatures less than –10°C or greater than 55°C.
c. Tx power for Ch 1 and Ch 11 is specified separately by nonvolatile memory parameters to ensure band-edge compliance.
11.4 General Spurious Emissions Specifications
Table 19. General Spurious Emissions Specifications
Parameter
Condition/Notes
Minimum
Typical
Maximum
Unit
Frequency range
–
2400
–
2500
MHz
General Spurious Emissions
Tx Emissions
30 MHz < f < 1 GHz
RBW = 100 kHz
RBW = 1 MHz
RBW = 1 MHz
RBW = 1 MHz
RBW = 100 kHz
RBW = 1 MHz
RBW = 1 MHz
RBW = 1 MHz
–
–
–
–
–
–
–
–
–99
–44
–68
–88
–99
–54
–88
–88
–96
–41
–65
–85
–96
–51
–85
–85
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
1 GHz < f < 12.75 GHz
1.8 GHz < f < 1.9 GHz
5.15 GHz < f < 5.3 GHz
30 MHz < f < 1 GHz
Rx/standby
Emissions
1 GHz < f < 12.75 GHz
1.8 GHz < f < 1.9 GHz
5.15 GHz < f < 5.3 GHz
Note: The specifications in this table are at the RF port.
Document No. 002-14779 Rev. *G