BCM4319 Preliminary Data Sheet
Operating Conditions
Section 10: Operating Conditions
Note: Values in this data sheet are design goals and are subject to change based on the results of
device characterization.
Environmental Ratings
Table 9: Environmental Characteristics
Characteristic
Value
Units
Conditions/Comments
–30 to +85a
–40 to +105
Less than 60
Less than 85
+ 2
Ambient temperature (TA)
°C
Operation
Storage temperature
Relative humidity
°C
%
–
Storage
%
Operation
ESD
kV
Human Body model
a. The BCM4319 supports a functional operating range of –30° to +85° C. However, the optimal RF performance
specified in this datasheet is only guaranteed for temperatures from –10° to +55° C.
Absolute Maximum Ratings
These specifications indicate levels where permanent damage to the device can occur. Functional operation is
not guaranteed under these conditions. Operation at absolute maximum conditions for extended periods can
adversely affect long-term reliability of the device.
Table 10: Absolute Maximum Ratings
Rating
Symbol
Value
Unit
DC supply voltage for VBAT
DC supply voltage for I/O
VBAT
–0.5 to +6.5
–0.5 to +4.1
V
V
VDDOa
VDDRF
VDDC
DC supply voltage for RF
–0.5 to +1.32
–0.5 to +1.32
–0.5
V
DC supply voltage for core
V
Maximum undershoot voltage for I/O
Maximum junction temperature
Vundershoot
Tj
V
125
°C
a. VDDO = VDDIO/VDDIO_SD/VDDIO_RF