CY7C419/21/25/29/33
Operating Range
Range
Commercial
Industrial
Military
Ambient Temperature[2]
VCC
0°C to + 70°C
–40°C to +85°C
–55°C to +125°C
5V ± 10%
5V ± 10%
5V ± 10%
Electrical Characteristics Over the Operating Range[3]
7C419–10, 15, 30, 40
7C420/1–10, 15, 20, 25, 30, 40, 65
7C424/5–10, 15, 20, 25, 30, 40, 65
7C428/9–10, 15, 20, 25, 30, 40, 65
7C432/3–10, 15, 20, 25, 30, 40, 65
Parameter
VOH
Description
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Test Conditions
VCC = Min., IOH = –2.0 mA
VCC = Min., IOL = 8.0 mA
Min.
Max.
Unit
V
2.4
VOL
0.4
VCC
VCC
0.8
V
VIH
Com’l
Mil/Ind
2.0
2.2
V
VIL
IIX
Input LOW Voltage
Note 4
–10
V
Input Leakage Current
Output Leakage Current
Output Short Circuit Current[5]
GND < VI < VCC
+10
+10
–90
µA
µA
mA
IOZ
IOS
R > VIH, GND < VO < VCC
VCC = Max., VOUT = GND
–10
Electrical Characteristics Over the Operating Range[3] (continued)
7C419–10
7C419–15
7C420–20
7C421–20
7C424–20
7C425–20
7C428–20
7C429–20
7C420–25
7C421–25
7C424–25
7C425–25
7C421–10
7C425–10
7C429–10
7C433–10
7C421–15
7C425–15
7C429–15
7C433–15
7C429–25
7C432–25
7C433–25
7C433–20
Parameter
Description
Test Conditions
Min. Max. Min. Max. Min. Max. Min. Max. Unit
ICC
Operating Current
VCC = Max.,
IOUT = 0 mA
f = fMAX
Com’l
85
65
55
90
50
80
mA
Mil/Ind
100
ICC1
Operating Current
Standby Current
VCC = Max.,
IOUT = 0 mA
F = 20 MHz
Com’l
35
35
35
35
mA
ISB1
All Inputs =
VIH Min.
Com’l
Mil/Ind
Com’l
Mil/Ind
10
5
10
15
5
10
15
5
10
15
5
mA
mA
ISB2
Power-Down Current All Inputs >
VCC –0.2V
8
8
8
Notes:
2. TA is the “instant on” case temperature.
3. See the last page of this specification for Group A subgroup testing information.
4. VIL (Min.) = –2.0V for pulse durations of less than 20 ns.
5. For test purposes, not more than one output at a time should be shorted. Short circuit test duration should not exceed 30 seconds.
Document #: 38-06001 Rev. *A
Page 3 of 22