USE ULTRA37000TM FOR
ALL NEW DESIGNS
PALCE22V10
AC Test Loads and Waveforms
R1238Ω
(319Ω MIL)
R1238Ω
(319Ω MIL)
5V
5V
OUTPUT
OUTPUT
OUTPUT
750Ω
R2170Ω
(236Ω MIL)
R2170Ω
(236Ω MIL)
(1.2KΩ
C
L
5pF
C
L
MIL)
INCLUDING
JIG AND
SCOPE
INCLUDING
JIG AND
SCOPE
(a)
(b)
(c)
ALL INPUT PULSES
90%
3.0V
90%
10%
10%
GND
< 2ns
< 2ns
(d)
Equivalent to:THÉVENIN Equivalent (Commercial)
Equivalent to: THÉVENIN Equivalent (Military)
99Ω
136Ω
OUTPUT
2.08V = VTHC
OUTPUT
2.13V = VTHM
Load Speed
CL
Package
5, 7.5, 10, 15, 25 ns
50 pF
PDIP, CDIP,
PLCC, LCC
Parameter VX
Output Waveform Measurement Level
tER (- )
tER (+)
tEA (+)
tEA (- )
1.5V
2.6V
0V
VOH
VX
VX
0.5V
0.5V
VOL
1.5V
VOH
VX
VX
Vthc
VOL
0.5V
(e) Test Waveforms
[2, 7]
Commercial Switching Characteristics PALCE22V10
22V10-5
22V10-7
22V10-10
22V10-15
22V10-25
Parameter
Description
Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Unit
tPD
Input to Output
3
5
3
7.5
3
10
3
15
3
25
ns
Propagation Delay[8]
tEA
tER
Input to Output Enable Delay[9]
Input to Output Disable Delay[10]
Clock to Output Delay[8]
6
6
4
8
8
5
10
10
7
15
15
8
25
25
15
ns
ns
ns
tCO
2
2
2
2
2
Notes:
7. Part (a) of AC Test Loads and Waveforms is used for all parameters except t and t
. Part (b) of AC Test Loads and Waveforms is used for t . Part (c) of AC Test
ER
ER
EA(+)
Loads and Waveforms is used for t
.
EA(+)
8. Min. times are tested initially and after any design or process changes that may affect these parameters.
9. The test load of (a) of AC Test Loads and Waveforms is used for measuring t . The test load of (c) of AC Test Loads and Waveforms is used for measuring t
only.
EA(+)
EA(-)
Please see (e) of AC Test Loads and Waveforms for enable and disable test waveforms and measurement reference levels.
10. This parameter is measured as the time after output disable input that the previous output data state remains stable on the output. This delay is measured to
the point at which a previous HIGH level has fallen to 0.5V below V min. or a previous LOW level has risen to 0.5V above V max. Please see (e) of AC Test Loads
OH
OL
and Waveforms for enable and disable test waveforms and measurement reference levels.
Document #: 38-03027 Rev. *B
Page 5 of 13