欢迎访问ic37.com |
会员登录 免费注册
发布采购

4D1225-B-10 参数 Datasheet PDF下载

4D1225-B-10图片预览
型号: 4D1225-B-10
PDF下载: 下载PDF文件 查看货源
内容描述: [Solid State Relay]
分类和应用:
文件页数/大小: 3 页 / 1023 K
品牌: CRYDOM [ CRYDOM INC., ]
 浏览型号4D1225-B-10的Datasheet PDF文件第2页浏览型号4D1225-B-10的Datasheet PDF文件第3页  
10-90A
mp
• 120/240 V
ac
- AC OUTPUT
Zero Voltage and Random
Turn-On Switching
Panel Mount
600V Transient Capability
Internal Snubber
110 & 125A Models
Available
Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
MODEL NUMBERS
AC CONTROL
D C CONTROL
A1210
D1210
A1225
D1225
A1240
D1240
S
eries
1
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications. Output
consists of an SCR AC switch and is
available in zero-cross, random turn-
on (phase controllable) and normally
closed (Form B) versions with either
AC or DC input (coil) control.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
A2425
D2425
A2450
D2450
A2475
D2475
A2490
D2490
A2410
D2410
OUTPUT SPECIFICATIONS
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
24-140
10
40
400
120
1.6
1.48
60
8
500
24-140
25
40
400
250
1.6
1.02
260
8
500
24-140
40
40
400
625
1.6
0.63
1620
8
500
24-280
10
40
600
120
1.6
1.48
60
10
500
24-280
25
40
600
250
1.6
1.02
260
10
500
24-280
50
40
600
625
1.6
0.63
1620
10
500
24-280
75
40
600
1000
1.6
0.31
4150
10
500
24-280
90
40
600
1200
1.6
0.28
6000
10
500
[Arms]
Min. Load Current, [mArms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R
θJC
[˚C/W]
)
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
0.5
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec(AC Control)
0.5
0.5
0.5
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS
Control Voltage Range
Max. Reverse Voltage
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current
DC CONTROL
3-32 Vdc
-32 Vdc
3.0 Vdc
1.0 Vdc
1500 Ohms
AC CONTROL
90-280 Vrms (60Hz)
---
90 Vrms
10 Vrms
60K Ohms
2mA @ 120 Vrms, 4mA @ 240 Vrms
AC CONTROL
(E SUFFIX)
18-36 Vrms
---
18 Vrms
4.0 Vrms
9.0K Ohms
3mA @ 24 Vrms
3.4mA @ 5 Vdc, 20mA @ 28Vdc
GENERAL NOTES
© 2003 CRYDOM CORP, Specifications subject to change without notice.
All parameters at 25˚ C unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Heat sinking required, for derating curves see page 3.
Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
For recommended applications and more information contact:
USA: Sales Support
(877) 502-5500
Tech Support
(877) 702-7700
FAX
(619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email:
sales@crydom.com
WEB SITE:
http://www.crydom.com
UK:
+44 (0)1202 365070 •
FAX
+44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE,
Email:
intsales@crydom.com.
GERMANY:
+49 (0)180 3000 506
FastFax Document No. 151
SERIES1
Rev. 102104
PAGE 1 OF 3