欢迎访问ic37.com |
会员登录 免费注册
发布采购

SMTR28512T/KR 参数 Datasheet PDF下载

SMTR28512T/KR图片预览
型号: SMTR28512T/KR
PDF下载: 下载PDF文件 查看货源
内容描述: SMTR单,双和三DC / DC转换器 [SMTR Single, Dual and Triple DC/DC Converters]
分类和应用: 转换器
文件页数/大小: 21 页 / 1371 K
品牌: CRANE [ Crane Aerospace & Electronics. ]
 浏览型号SMTR28512T/KR的Datasheet PDF文件第13页浏览型号SMTR28512T/KR的Datasheet PDF文件第14页浏览型号SMTR28512T/KR的Datasheet PDF文件第15页浏览型号SMTR28512T/KR的Datasheet PDF文件第16页浏览型号SMTR28512T/KR的Datasheet PDF文件第17页浏览型号SMTR28512T/KR的Datasheet PDF文件第18页浏览型号SMTR28512T/KR的Datasheet PDF文件第19页浏览型号SMTR28512T/KR的Datasheet PDF文件第21页  
Crane Aerospace & Electronics Power Solutions  
SMTR Single, Dꢀꢁl ꢁnd Triple DC/DC Converters  
28 VOꢂT INPuT – 30 WaTT – PENDINꢃ REVISION F REꢂEaSE  
cl a S S  
h
a n D K, mil-prF-38534 en v i r o n m e n t a l  
Sc r e e n i n g  
end Item-LeveL test  
performed  
spaCe prototype (o)  
non-QmL1  
CLass H  
QmL  
CLass K  
QmL  
2
3
Non-destruct bond pull  
no  
yes  
yes  
Method 2023  
Pre-cap Inspection  
Method 2017, 2032  
yes  
yes  
yes  
Temperature Cycle (10 times)  
Method 1010, Cond. C, -65°C to 150°C, ambient  
yes  
yes  
yes  
yes  
yes  
yes  
Constant Acceleration  
Method 2001, 3000 g  
PIND Test  
3
Method 2020, Cond. A, 70 g @ 40 -200 Hz.  
no  
yes  
yes  
yes  
Pre burn-in test  
yes  
yes  
Burn-in  
Method 1015, 125°C case, typical  
96 hours  
160 hours  
yes  
no  
no  
no  
yes  
no  
no  
no  
yes  
2 x 160 hours (includes mid-BI test)  
Final Electrical Test MIL-PRF-38534  
Group A, Subgroups 1 through 6  
-55°C, +25°C, +125°C case  
yes  
N/A  
N/A  
yes  
N/A  
N/A  
yes  
yes  
Radiography  
Method 2012  
Post Radiography Electrical Test  
Room temperature  
3
yes  
Hermeticity Test  
Fine Leak, Method 1014, Cond. A  
Gross Leak, Method 1014, Cond. C  
yes  
yes  
yes  
yes  
yes  
yes  
Final visual inspection  
Method 2009  
yes  
yes  
yes  
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.  
Notes:  
1. Space Prototype (O), non-QML products, do not meet all of the requirements of MIL-PRF-38534.  
2. Not applicable to EMI filters that have no wirebonds.  
3. Not required by DSCC but performed to assure product quality.  
www.interpoint.com  
Page 20 of 21  
Rev F - 20090324 - Pending Revision F Release  
 复制成功!