Crane Aerospace & Electronics Power Solutions
SMTR Single, Dꢀꢁl ꢁnd Triple DC/DC Converters
28 VOꢂT INPuT – 30 WaTT – PENDINꢃ REVISION F REꢂEaSE
Electrical Characteristics: -55 to +125° C T , 28 VDC Vin, 100% load, no irraditaion, unless otherwise specified.
C
TRIPLE OUTPUT MODEL – SMRT28515T
5 (MAIꢀ)
TYP
5.00
5.00
—
+15 (+AUX)
-15 (-AUX)
TYP MAX
unitS
parameter
COnDitiOnS
MIꢀ
4.95
4.85
0.30
—
MAX
5.05
5.15
4.00
20
MIꢀ
TYP
MAX
MIꢀ
Output VOltage
25°C
14.77 15.00 15.23 -14.77 -15.00 -15.23
14.47 15.00 15.52 -14.47 -15.00 -15.52
VDC
A
2, 3
Output Current
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
±0.50
7.5
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
±0.50
7.5
—
2, 3
Output pOwer
—
W
tOtal all OutputS
10 khz - 2 mhz
—
—
30
Output ripple
line regulatiOn
lOaD regulatiOn
input VOltage
—
—
180
20
120
75
75
—
120
75
75
—
mV p-p
mV
4
Vin 16 t O 40 VDC
—
—
3, 4
—
—
50
mV
COntinuOuS
16
28
40
VDC
V
1
tranSient 50 ms
—
—
50
—
—
input Current
nO lOaD
inhiBiteD
10 kHz - 10 MHz
25°C
—
—
110
6
—
—
mA
—
—
—
—
3
input ripple Current
eFFiCienCy
—
—
80
—
—
mA p-p
%
72
73
—
—
—
70
—
—
—
—
5
lOaD Fault
pOwer DiSSipatiOn
reCOVery eaCh
—
—
14
—
—
W
all OutputS ShOrteD
—
—
6
—
—
—
—
—
—
ms
1
Output
6, 7
Step lOaD reSpOnSe
tranSient
reCOVery
—
—
—
—
±400
0.30
—
—
—
—
±1500
6
—
—
—
—
±1500
6
mV pk
ms
1
Step line reSpOnSe
Start-up
Vin 16 t O 40 VDC
tranSient
—
—
±800
—
—
±800
—
—
±800
mV pk
reCOVery
Delay
—
—
—
—
5
6
—
—
—
—
5
6
—
—
—
—
5
6
ms
ms
1
OVerShOOt
—
—
500
—
—
2000
—
—
2000
mV pk
ꢀotes:
(All temperatures in tables and notes refer to case temperature, TC.)
1. ꢃꢀꢁrꢁnteed ꢆꢄ design, not tested.
2. The sum of the two Aux outputs is not to exceed 10 watts. The maximum load
per Aux output is 7.5 watts.
3. To maintain regulation when operating the ±Aux at full load, a minimum load of
300 mA is required on the main output. For Aux loads less than full load, a lower
load (<300 mA) on the main output will maintain regulation.
6. Response of each output as all outputs are simultaneously transitioned.
Main: 50% - 100% - 50% of main full load
Auxiliaries: 25% - 50% - 25% each, of total auxiliary full load
7.Recovery time is measured from application of the transient to point at which
Vout is within 1% of regulation.
8. Tested on release from inhibit.
4. Measured on each output one at a time with the other outputs at full load.
5. Indefinite short circuit protection not guaranteed above 125°C (case).
www.interpoint.com
Page 11 of 21
Rev F - 20090324 - Pending Revision F Release