QA SCREENING
85°C PRODUCTS
85°C PRODUCTS
TEST (85°C Products excluding HR products)
STANDARD
/ES
yes
yes
yes
yes
yes
PRE-CAP INSPECTION
Method 2017
yes
no
TEMPERATURE CYCLE (10 times)
Method 1010, Cond. B, -55°C to 125°C
CONSTANT ACCELERATION
Method 2001, 500 g
no
BURN-IN
96 hours at 70°C ambient (typical)
FINAL ELECTRICAL TEST MIL-PRF-38534, Group A
Subgroups 1 and 4: +25°C case
HERMETICITY TESTING
no
yes
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
no
no
yes
yes
no
-3
Gross Leak, Dip (1 x 10 )
yes
FINAL VISUAL INSPECTION
Method 2009
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Applies to the following products:
MFW Series
MTW Series
MHE/MLP Series
MHL Series
MRH Series
MTO Series
MSR Series
DCH Series
FM/FMA/FMB EMI Filters
MSF EMI Filter
C2-12