Crane Aerospace & Electronics Power Solutions
MOR Single and Dual DC/DC Converters
28 VOLT INPUT – 120 WATT
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
MOR286R3D
MOR289R5D
MOR2812D
MOR2815D
CONDITIONS
MIN TYP MAX
6.24 6.30 6.36
6.22 6.30 6.38
MIN TYP MAX
9.41 9.50 9.58
9.36 9.50 9.63
MIN TYP MAX
11.88 12.00 12.12
11.82 12.00 12.18
MIN TYP MAX
14.85 15.00 15.15
14.77 15.00 15.23
UNITS
5
+V
–V
OUT
OUT
VDC
6
6
OUTPUT CURRENT
V
V
= 16 to 40 VDC
= 16 to 40 VDC
—
—
8
16
—
—
5.53 11.05
—
—
4.58 9.16
—
—
4.00 8.00
A
IN
OUTPUT POWER
—
100
—
105
—
110
—
120
W
IN
OUTPUT RIPPLE
VOLTAGE
10 kHz - 20 MHz
Tc = –55°C to +125°C
10 kHz - 2 MHz
—
50
100
—
75
120
—
75
120
—
75
150
mV p-p
+V
/ –V
OUT
OUT
Tc = –55°C to +125°C
—
—
—
30
25
50
60
50
160
—
—
—
50
25
50
80
50
100
—
—
—
50
25
50
100
50
100
—
—
—
50
25
50
120
50
100
LINE REGULATION
= 16 to 40 VDC
+V
–V
OUT
OUT
mV
V
IN
LOAD REGULATION
+V
–V
—
—
25
50
50
200
—
—
25
50
50
200
—
—
25
50
50
200
—
—
25
50
50
200
OUT
OUT
mV
%
7
CROSS REGULATION
INPUT VOLTAGE
NEGATIVE V
—
5
8
—
4
7
—
3
5
—
2
4
OUT
CONTINUOUS
TRANSIENT 120 msec
NO LOAD
INHIBITED - INH1
INHIBITED - INH2
10 kHz - 20 MHz
Tc = –55°C to +125°C
16
—
—
—
—
28
—
70
—
—
40
50
140
10
16
—
—
—
—
28
—
70
—
—
40
50
140
10
16
—
—
—
—
28
—
70
—
—
40
50
140
10
16
—
—
—
—
28
—
70
—
—
40
50
140
10
VDC
V
mA
1
INPUT CURRENT
mA
70
60
70
70
INPUT RIPPLE
CURRENT
EFFICIENCY
—
81
—
83
130
—
—
82
—
84
130
—
—
84
—
86
130
—
—
85
—
87
130
—
mA p-p
%
LOAD FAULT
POWER DISSIPATION
OVERLOAD
—
—
—
30
—
—
—
24
10
—
—
—
30
—
—
—
24
10
—
—
—
30
—
—
—
24
10
—
—
—
30
—
—
—
20
10
W
2
SHORT CIRCUIT
1
RECOVERY
ms
STEP LOAD RESP.
50% – 100% — 50%
TRANSIENT
V
—
—
—
—
500
300
—
—
—
—
500
300
—
—
—
—
600
300
—
—
—
—
600
300
mV pk
μs
OUT
3
RECOVERY
STEP LINE RESP.
16 – 40 – 16 VDC
1, 4
V
TRANSIENT
RECOVERY
—
—
—
—
—
—
—
—
—
0.1
500
300
10
50
1.0
—
—
—
—
—
—
—
—
—
0.1
600
300
10
50
1.0
—
—
—
—
—
—
—
—
—
0.1
600
300
10
50
1.0
—
—
—
—
—
—
—
—
—
0.1
750
300
10
50
1.0
mV pk
μs
ms
mV pk
mA
OUT
1, 3
8
START-UP
DELAY
OVERSHOOT
1
1
INHIBIT PIN CURRENT
CAPACITIVE LOAD
UNIT INHIBITED
NO EFFECT ON DC
PERFORMANCE
1
—
—
1000
—
—
1000
—
—
1000
—
—
1000
μF
Notes:
1. Guaranteed by design, not tested.
of that total is available from either output provided the other output
maintains a minimum of 15% the total power used.
7. Effect on negative Vout from 50%/50% loads to 70%/30% or 30%/70%
loads.
2. Short circuit is measured with a 10 mΩ ( 10%)resisitive load.
3. Time to settle to within 1% of Vout.
4. Transition time > 10 μs
5. Output voltage for dual output models is measured at half load.
8. Tested on release from inhibit.
6. The maximum specification is the total output current/power. Up to 70%
www.craneae.com
Page 9 of 21
Rev G - 20060418