Crane Aerospace & Electronics Power Solutions
MOR Single and Dual DC/DC Converters
28 VOLT INPUT – 120 WATT
883, CLASS H, QML PRODUCTS – ENVIRONMENTAL
SCREENING
TEST
125°C
125°C
/ES
non-QML
Class H
/883
QML
STANDARD
1
1
non-QML
Pre-cap Inspection
Method 2017, 2032
yes
yes
yes
Temperature Cycle (10 times)
Method 1010, Cond. C, -65°C to 150°C, ambient
Method 1010, Cond. B, -55°C to 125°C, ambient
no
no
no
yes
yes
no
Constant Acceleration
Method 2001, 3000 g
Method 2001, 500g
no
no
no
yes
yes
no
Burn-In
Method 1015, 160 hours at 125°C case, typical
96 hours at 125°C case, typical
no
no
no
yes
yes
no
Final Electrical Test MIL-PRF-38534, Group A
Subgroups 1 through 6: -55°C, +25°C, +125°C case
Subgroups 1 and 4: +25°C case
no
yes
no
yes
yes
no
Hermeticity Test
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
no
no
yes
yes
yes
no
yes
yes
no
-3
Gross Leak, Dip (1 x 10 )
Final Visual Inspection
Method 2009
yes
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Notes:
1. Non-QML products do not meet all of the requirements of MIL-PRF-38534
MOR Single and Dual Rev G - 20060418. This revision supercedes all previous releases. All technical information is believed to be accurate, but no responsibility is
assumed for errors or omissions. Interpoint reserves the right to make changes in products or specifications without notice. MOR Series is a trademark of Interpoint.
Copyright © 1999 - 2006 Interpoint Corporation. All rights reserved. www.craneae.com