欢迎访问ic37.com |
会员登录 免费注册
发布采购

MHP27012DF/ES 参数 Datasheet PDF下载

MHP27012DF/ES图片预览
型号: MHP27012DF/ES
PDF下载: 下载PDF文件 查看货源
内容描述: [MHP27005S]
分类和应用:
文件页数/大小: 10 页 / 399 K
品牌: CRANE [ Crane Aerospace & Electronics. ]
 浏览型号MHP27012DF/ES的Datasheet PDF文件第2页浏览型号MHP27012DF/ES的Datasheet PDF文件第3页浏览型号MHP27012DF/ES的Datasheet PDF文件第4页浏览型号MHP27012DF/ES的Datasheet PDF文件第5页浏览型号MHP27012DF/ES的Datasheet PDF文件第6页浏览型号MHP27012DF/ES的Datasheet PDF文件第7页浏览型号MHP27012DF/ES的Datasheet PDF文件第9页浏览型号MHP27012DF/ES的Datasheet PDF文件第10页  
Crane Aerospace & Electronics Power Solutions
MHp270 single and dual dc/dc converters
270 Volt input – 65 Watt
Electrical Characteristics: 25°C Tc, 270 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL oUTPUT MoDELS
paraMeter
Output VOltage
Output Current
2
Output pOWer
2
Output ripple
±V
Out
1
MHp27005D
Min
4.95
4.92
0
0
160
0
74
tYp
5.00
5.00
±5
50
270
MaX
5.05
5.08
8.0
50
100
100
100
1000
400
450
20
10
15
60
30
300
300
Min
MHp27012D
tYp
12.00
12.00
±2.5
50
270
_
MaX
12.12
12.18
4.0
60
125
120
120
800
400
450
20
10
15
60
35
900
500
Min
11.88
11.82
0
0
160
0
81
MHp28015D
tYp
15.00
15.00
±2.16
50
270
_
MaX
15.15
15.23
3.46
65
125
150
150
750
400
450
20
8
15
60
45
900
500
14.85
14.77
0
0
160
0
82
COnDitiOns
+V
Out
-V
Out
V
in
= 160
V
in
= 160
tO
tO
units
VDC
a
W
mV p-p
mV
mV
mV
VDC
V
mA
mA p-p
%
W
mV pk
µs
400 VDC
400 VDC
10
k
H
z
- 2 MH
z
V
in
= 160
tO
400 VDC
nO lOaD tO Full
eFFeCt
On
line regulatiOn
±V
Out
lOaD regulatiOn
3
±V
Out
input VOltage
CrOss regulatiOn
4
–V
Out
COntinuOus
TRANSIENT 50 msec.
4
nO lOaD
inHiBiteD–inH1
inHiBiteD–inH2
input Current
input ripple
Current
eFFiCienCY
lOaD Fault
step lOaD
respOnse
±V
Out
10
k
H
z
- 10 MH
z
BalanCeD lOaD
pOWer DissipatiOn
sHOrt CirCuit
50% - 100% - 50%
6
transient
reCOVerY
7
Notes
1. Share operation not characterized for dual outputs.
2. Up to 80% of the total output power is available from either output
provided that the opposite output is simultaneously carrying 20% of the
total output power. one of the outputs must always provide a minimum
of 20% of the total output power to meet cross regulation. Negative Vout
cross regulation is referenced to 50%/50% balanced loads (at 100% of
total rated output power - full load).
3. Assumes balanced loads on the outputs.
4. Effect on the negative output from 50%/50% loads to 70%/30% or
70%/30% loads.
5. Unit will shut down above approximately 425V but will be undamaged
and will restart when voltage drops into normal range.
6. Second output at 50%
7. Recovery time is measured from application of the transient to point at
which Vout is within 1% of final value.
www.interpoint.com
Rev F - 20090304
Page 8 of 10