Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
MGH DUAL OUTPUT MODELS
MGH2805D
MGH2812D
MGH2815D
PARAMETER
CONDITIONS
MIN
4.95
4.80
TYP
MAX
5.05
5.20
MIN
TYP
MAX
12.12
12.48
MIN
TYP
MAX
15.15
15.60
UNITS
1
OUTPUT VOLTAGE
Tc = 25°C
5
11.88
12
14.85
15
VDC
Tc = –55°C TO +125°C
5
11.52
0
0
—
—
12
14.40
15
2
OUTPUT CURRENT
V
= 12 to 50 VDC
= 12 to 50 VDC
10 kHz - 2 MHz
0
150
240
62.5
100
0
0
—
—
50
80
mA
W
IN
IN
OUTPUT POWER
OUTPUT RIPPLE
V
0
—
—
—
35
50
1.5
150
250
—
35
40
1.5
150
250
—
30
35
1.5
150
250
VOLTAGE +V
Tc = –55°C TO +125°C
mV p-p
V
OUT
OUT
–V
10 kHz - 2 MHz
—
—
35
150
—
—
35
150
—
—
30
150
Tc = –55°C TO +125°C
50
250
40
250
35
250
3
LINE REGULATION
VIN = 12 to 50 VDC
—
10
20
50
—
100
110
300
400
—
165
180
500
650
Tc = –55°C TO +125°C
—
100
—
—
LOAD
3
REGULATION , 4
10% TO FULL LOAD
–55°C TO +125°C
—
—
300
350
600
700
—
—
550
570
1100
1200
—
—
600
630
1300
1400
mV
mV
50% TO FULL LOAD
—
80
200
—
115
250
—
125
300
–55°C TO +125°C
—
100
300
—
130
350
—
135
400
CROSS
5
REGULATION
–V
—
—
400
—
—
500
—
—
500
OUT
INPUT VOLTAGE
CONTINUOUS
12
28
50
12
28
50
12
28
50
VDC
V
NO LOAD TO FULL
TRANSIENT 120 ms
0
—
80
0
—
80
0
—
70
INPUT CURRENT
NO LOAD
—
—
5.0
6.0
10
12
—
—
7.5
8.0
13
14
—
—
7.5
8.0
13
14
Tc = –55°C TO +125°C
FULL LOAD
—
69
73
—
70
73
—
71
74
mA
Tc = –55°C TO +125°C
—
72
77
—
71
77
—
72
78
INHIBITED
—
—
2.3
2.4
3.2
3.5
—
—
2.3
2.4
3.2
3.5
—
—
2.3
2.4
3.2
3.5
Tc = –55°C TO +125°C
6
INPUT RIPPLE
10 kHz - 10 MHz
—
100
200
—
115
200
—
90
200
mA p-p
%
CURRENT
Tc = –55°C TO +125°C
—
130
250
—
150
250
—
120
250
EFFICIENCY
Tc = 25°C
73
70
77
75
—
—
73
70
77
75
—
—
72
69
76
—
—
Tc = –55°C TO +125°C
74
7,8
LOAD FAULT
POWER DISSIPATION
—
1.4
2.2
—
2.5
3.8
—
2.7
3.0
4.1
W
Tc = –55°C TO +125°C
—
1.6
2.5
—
2.7
4.2
—
4.5
RECOVERY
—
—
3.7
3.8
15
20
—
—
3.2
3.2
15
20
—
—
4.0
15
20
ms
Tc = –55°C TO +125°C
4.0
STEP LOAD
TRANSIENT
–300
130
300
–600
250
600
–600
250
270
600
mV pk
μs
9
RESPONSE
Tc = –55°C TO +125°C
–400
140
400
–700
260
700
–700
700
V
RECOVERY
—
—
100
100
400
500
—
—
165
165
700
800
—
—
50
200
300
out
50 %–100%– 50%
STEP LINE
–55°C TO +125°C
50
TRANSIENT
–250
125
250
–500
240
500
–500
220
230
500
mV pk
ms
19
RESPONSE
Tc = –55°C TO +125°C
–300
130
300
–600
250
600
–600
600
V
RECOVERY
—
—
0.6
0.6
2.5
3.0
—
—
0.9
0.9
3.0
4.0
—
—
0.6
3.0
4.0
out
12 TO 50 TO 12 V
Tc = –55°C TO +125°C
0.7
IN
START–UP
DELAY
—
8
25
—
8
25
—
8
25
ms
0 TO 28 VDC,
V
Tc = –55°C TO +125°C
—
10
45
—
10
45
—
10
45
out
OVERSHOOT
—
—
0
100
150
—
—
0
250
350
—
—
0
750
900
mV pk
Tc = –55°C TO +125°C
0
0
0
Notes:
1. Specified at 50% load.
ages of total output power: +Po = 20% and
–Po = 80% to +Po=80% and –Po=20%
6. Lin = 2 μH.
2. Max. spec indicates 80% of the converter’s total available power. This 80%
is available from either output.
3. Specification applies to both + and –Vout.
7. Max. duration of short circuit: 25°C – 90 seconds; 125°C – 30 seconds.
8. Load fault is a short circuit (<50 mohms). Recovery into resistive full load.
9. Input step transition ≥ 10 μs.Recovery is time to settle to within 1% of Vout
final value.
4. Although no minimum load is required, at no load the output voltage may
increase up to 15%.
5. Cross regulation is specified as the effect on –Vout for the following percent
www.craneae.com
Page 10 of 18
Rev E - 20060508