DC/DC C
ONVERTERS
DUAL OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
CONDITIONS
+V
OUT
–V
OUT
OUTPUT CURRENT
OUTPUT POWER
1
OUTPUT RIPPLE
2
LINE REGULATION
V
IN
= 16 to 40 VDC
LOAD REGULATION
NO LOAD TO FULL
CROSS REG.
3
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
V
IN
= 16 to 40 VDC
V
IN
= 16 to 40 VDC
10 kHz - 2 MHz
+V
OUT
–V
OUT
+V
OUT
(BALANCED)
–V
OUT
(BALANCED)
EFFECT ON –V
OUT
CONTINUOUS
TRANSIENT 50 ms
NO LOAD
FULL LOAD
INHIBITED
INPUT RIPPLE
10 kHz - 10 MHz
EFFICIENCY
LOAD FAULT
4
SHORT CIRCUIT
POWER DISS.
RECOVERY
STEP LOAD
RESP O N S E
5, 6
STEP LINE
RESP O N S E
8
TRANSIENT
RECOVERY
7
16 – 40 – 16 VDC
TRANSIENT
RECOVERY
7
START-UP
OVERSHOOT
DELAY
INHIBIT PIN
CURRENT
CAPACITANCE
CAPACITIVE LOAD
UNIT INHIBITED
INPUT TO OUTPUT
—
—
—
2.5
50
—
4.0
—
100
—
—
—
2.5
50
—
–500
—
0
0
100
0.8
200
10
500
2.0
500
30
–1500 200
—
0
0
1.6
200
10
—
—
–550
—
1.3
10
180
200
1.7
30
550
500
—
—
–600
—
1.3
10
180
200
Tc = 25°C
Tc = –55°C to +125°C
MGA2805D
MGA2812D
MIN
11.88
TYP MAX
12
12.12
MGA2815D
MIN
14.85
MGA SERIES
5 WATT
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
TYP MAX
15
15.15
UNITS
VDC
mA
W
mV p-p
mV
–11.76 –12 –12.24
0
—
—
—
—
—
—
—
16
—
—
±208 333
—
120
10
40
10
50
8
28
—
33
—
3
50
75
73
5
300
50
180
50
200
15
40
50
63
267
4
200
300
—
–14.70 –15 –15.30
0
—
—
—
—
—
—
—
16
—
—
—
—
—
—
68
±167
—
120
10
40
10
50
7
28
—
38
—
3
50
75
73
267
5
300
50
180
50
200
15=
40
50
63
263
4
200
300
—
%
mA p-p
mA
%
VDC
V
mV
A
VAILABLE
SOON
,
ASK YOUR
I
NTERPOINT REP
FOR INFORMA
-
TION
—
—
—
—
67
1.6
30
600
500
W
ms
mV pk
µs
1500
4.0
500
30
mV pk
ms
mV pk
ms
4.0
—
100
mA
pF
µF
Notes
1. Up to 4 watts, 80% of the total output power is available from either output
providing the opposite output is simultaneously carrying 20% of the total
output power. Each output must carry a minimum of 20% of the total output
power in order to maintain regulation on the negative output.
2. Applies to both +Vout and –Vout
3. Cross regulation is specified for the following percentages of total output
power: +PO = 20% and –PO = 80% to +PO =80% and –PO = 20%
4. Indefinite short circuit protection not guaranteed above 125°C (case).
5. Load transient transition time is >10 µs.
6. Response of either output when the load for each output is simultaneously
transitioned from 25% to 50% to 25% of total output power (5 watts).
7. Recovery time is measured from application of the transient to the point at
which Vout is within regulation.
8. Input step transition time is >10µs.
B2-83