Crane Aerospace & Electronics Power Solutions
MFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
Electrical Characteristics: –55°C to +100°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
SINGLE OUTPUT MODELS
MFLHP2805S
MFLHP2812S
MFLHP2815S
UNITS
PARAMETER
CONDITIONS
TC = 25°C
MIN TYP MAX MIN TYP MAX MIN TYP MAX
4.95 5.00 5.05 11.88 12.00 12.12 14.85 15.00 15.15
OUTPUT VOLTAGE
OUTPUT CURRENT
OUTPUT POWER
VDC
A
VIN = 19 TO 40 VDC
VIN = 19 TO 40 VDC
0
0
—
—
16
80
0
0
—
—
7.5
90
0
0
—
—
6.67
100
W
OUTPUT RIPPLE
10 KHZ - 2 MHZ
TC = 25°C
TC = -55°C TO +100°C
—
—
15
30
35
75
—
—
30
45
75
125
—
—
30
45
85
150
mV p-p
LINE REGULATION
LOAD REGULATION
V
= 19 TO 40 VDC
—
—
19
—
0
20
20
—
—
0
20
20
—
—
0
20
20
40
80
mV
mV
VDC
V
IN
NO LOAD TO FULL
0
0
0
INPUT VOLTAGE
NO LOAD TO FULL
CONTINUOUS
28
—
40 19
28
40 19
28
—
2
1
TRANSIENT 50 msec.
80
—
—
80
—
INPUT CURRENT
NO LOAD
—
—
—
—
70
9
120
14
—
—
—
—
50
9
120
14
—
—
—
—
50
120
14
INHIBITED–INH1
INHIBITED–INH2
10 KHZ - 10 MHZ
9
mA
35
15
70
35
15
70
35
15
70
INPUT RIPPLE
CURRENT
50
50
50
mA p-p
%
EFFICIENCY
TC = 25°C
78
80
—
83
86
—
84
87
—
LOAD FAULT
TC = 25°C
POWER DISSIPATION
SHORT CIRCUIT
—
—
15
20
4
—
—
15
20
4
—
—
15
20
4
W
1
RECOVERY
1.5
1.5
1.5
m sec
STEP LOAD
RESPONSE
50% - 100% - 50%
TRANSIENT
—
—
350
1.5
450
3.0
—
—
450
1.5
700
3.0
—
—
450
700
3.0
mV pk
m s ec
3
RECOVERY
1.5
STEP LINE
RESPONSE
19 - 40 -19 VDC
TRANSIENT
1, 4
—
250
400
—
250
400
—
250
200
400
mV pk
1, 3
RECOVERY
—
—
200
3.5
300
6
—
—
200
3.5
300
6
—
—
300
6
μs
START-UP
DELAY
3.5
m sec
1
OVERSHOOT
—
0
25
—
0
50
—
0
50
mV pk
Notes:
1. Guaranteed by design, not tested.
2. Unit will shut down above approximately 45V but will be undamaged
and will restart when voltage drops into normal range.
3. Recovery time is measured from application of the transient to point at
which Vout is within 1% of final value.
4. Transition time ≥ 10 μs.
Page 6 of 11
Rev D - 20070703
www.craneae.com