Crane Aerospace & Electronics Power Solutions
MFLHP Single and Dual DC/DC Converters
28 VOLT INPUT – 100 WATT
Electrical Characteristics: –55°C to +100°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
SINGLE OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT
OUTPUT POWER
OUTPUT RIPPLE
10
K
H
Z
- 2 MH
Z
LINE REGULATION
LOAD REGULATION
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
CONDITIONS
TC = 25°C
V
IN
= 19
TO
40 VDC
V
IN
= 19
TO
40 VDC
TC = 25°C
TC = -55°C
TO
+100°C
V
IN
= 19
TO
40 VDC
NO LOAD TO FULL
CONTINUOUS
TRANSIENT
2
50 msec.
1
NO LOAD
INHIBITED–INH1
INHIBITED–INH2
INPUT RIPPLE
CURRENT
EFFICIENCY
LOAD FAULT
TC = 25°C
STEP LOAD
RESPONSE
STEP LINE
RESPONSE
START-UP
10
K
H
Z
- 10 MH
Z
TC = 25°C
POWER DISSIPATION
SHORT CIRCUIT
RECOVERY
1
50% - 100% - 50%
TRANSIENT
RECOVERY
3
19 - 40 -19 VDC
TRANSIENT
1, 4
RECOVERY
1, 3
DELAY
OVERSHOOT
1
MFLHP2805S
MIN
4.95
0
0
—
—
—
—
19
—
—
—
—
—
78
—
—
—
—
—
—
—
—
TYP
5.00
—
—
15
30
0
0
28
—
70
9
35
15
80
15
1.5
350
1.5
250
200
3.5
0
MAX
5.05
16
35
75
20
40
80
120
14
70
50
—
20
MFLHP2812S
MIN
0
—
—
—
19
—
—
—
—
—
83
—
TYP
—
—
30
45
0
0
28
—
50
9
35
15
86
15
1.5
450
1.5
250
200
3.5
0
MFLHP2815S
TYP
—
—
30
45
0
0
28
—
50
9
35
15
87
15
1.5
450
1.5
250
200
3.5
0
MAX
6.67
100
85
150
20
20
40
80
120
14
70
50
—
20
4
700
3.0
400
300
6
50
MAX MIN
7.5 0
90 0
75
125
—
—
UNITS
VDC
A
W
mV p-p
mV
mV
VDC
V
11.88 12.00 12.12 14.85 15.00 15.15
80 0
20 —
20 —
40
80
120
14
70
19
—
—
—
—
20 —
mA
50 —
— 84
20
—
mA p-p
%
W
m sec
mV pk
m sec
mV pk
μs
m sec
mV pk
4 —
450
3.0
400
300
25
—
—
—
—
—
4 —
700
3.0
400
300
50
—
—
—
—
—
6 —
6 —
Notes:
1. Guaranteed by design, not tested.
2. Unit will shut down above approximately 45V but will be undamaged
and will restart when voltage drops into normal range.
3. Recovery time is measured from application of the transient to point at
which Vout is within 1% of final value.
4. Transition time
≥
10
μs.
www.craneae.com
Page 6 of 11
Rev D - 20070703