Crane Aerospace & Electronics Power Solutions
MFL Single and Dual DC/DC Converters
28 VOLT INPUT – 65 WATT
Electrical Characteristics: –55°C to +125° C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
SINGLE OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT
OUTPUT POWER
OUTPUT RIPPLE
VOLTAGE 10 k - 2 MHz
LINE REGULATION
LOAD REGULATION
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
CONDITION
Tc = 25°C
V
IN
= 16 TO 40 VDC
V
IN
= 16 TO 40 VDC
Tc = 25°C
Tc = –55°C to +125°C
V
IN
= 16 to 40 VDC
NO LOAD TO FULL
CONTINUOUS
TRANSIENT
1,
3
50 ms
NO LOAD
INHIBITED - INH1
INHIBITED - INH2
INPUT RIPPLE
CURRENT
EFFICIENCY
LOAD FAULT
10 kHz - 10 MHz
Tc = 25°C
POWER DISSIPATION
SHORT CIRCUIT
Tc = 25°C
RECOVERY
1
STEP LOAD RESP.
50% – 100% – 50%
TRANSIENT
RECOVERY
1,
4
STEP LINE RESP.
16 – 40 – 16 VDC
TRANSIENT
1,
5
RECOVERY
1,
4
DELAY
OVERSHOOT
1,
Tc=25°C
1,
7
—
84
MFL2815S
MIN
TYP MAX
MFL2828S
2
MIN
TYP MAX
2
UNITS
VDC
A
W
mV p-p
mV
mV
VDC
V
mA
mA
14.85 15.00 15.15
0
0
—
—
—
—
16
—
—
—
—
—
—
30
45
0
0
28
—
50
9
35
15
87
4.33
65
85
110
20
20
40
50
100
14
70
50
—
27.72 28.00 28.28
0
0
—
—
—
—
16
—
—
—
—
—
83
—
—
100
—
20
20
28
—
60
9
35
20
86
2.32
65
200
—
60
75
40
50
100
14
70
50
—
mA pp
%
—
—
—
—
—
—
—
—
—
10
1.5
500
1.5
250
200
3.5
0
—
14
4
600
3.0
400
300
6
50
1000
—
—
—
—
—
—
—
—
—
7
1.0
14
4
W
ms
mV pk
ms
mV pk
μs
ms
mV pk
μF
800 1400
1.5
250
200
3.5
0
—
3.0
800
400
6
100
1000
START-UP
6
C
OUT
Notes
1. Guaranteed by design, not tested.
2. MFL2828S specifiications are at 25°Tc.
3. Unit will shut down above approximately 45V but will be undamaged and
will restart when voltage drops into normal range.
4. Recovery time is measured from application of the transient to point at
which Vout is within 1% of final value.
5. Transition time > 10 μs.
6. Tested on release from inhibit.
7. Shall not compromise DC performance
www.craneae.com
Page 7 of 13
Rev D - 20060601