FMSA EMI FILTER
0.8 AMP
EMI I
NPUT
F
ILTERS
QA SCREENING
125°C PRODUCTS
125°C P
RODUCTS
TEST (125°C Products)
125°C
STANDARD
125°C
/ES
/883 (Class H)*
Pre-cap Inspection
Method 2017, 2032
Temperature Cycle (10 times)
Method 1010, Cond. C, -65°C to 150°C, ambient
Method 1010, Cond. B, -55°C to 125°C, ambient
Constant Acceleration
Method 2001, 300 g
Method 2001, 500g
Burn-In
Method 1015, 160 hours at 125°C case, typical
96 hours at 125°C case, typical
Final Electrical Test MIL-PRF-38534, Group A
Subgroups 1 through 6: -55°C, +25°C, +125°C case
Subgroups 1 and 4: +25°C case
Hermeticity Test
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
Gross Leak, Dip (1 x 10
-3
)
Final Visual Inspection
Method 2009
yes
yes
yes
no
no
no
yes
yes
no
no
no
no
yes
yes
no
no
no
no
yes
yes
no
no
yes
no
yes
yes
no
no
no
yes
yes
yes
no
yes
yes
no
yes
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
*883 products are built with element evaluated components and are 100% tested and guaranteed over
the full military temperature range of –55°C to +125°C.
6
FMSA Rev B 20050522
All technical information is believed to be accurate, but no responsibility is
assumed for errors or omissions. Interpoint reserves the right to make changes in
products or specifications without notice. FMSA Series is a trademark of
Interpoint. Copyright © 1994 - 2005 Interpoint. All rights reserved.
®