Ordering information
DC-DC Converters PCB Mount Type
MG W
10
24
12 -O
5 6
MGW10
1
2
3
4
1Series name
2Dual output
R
3Output wattage
4Input voltage
5Output voltage
6Optional
Y2: Output voltage
adjustable (ꢀ10%, -5%)
MODEL
MGW100512 MGW100515 MGW101212 MGW101215 MGW102412 MGW102415 MGW104812 MGW104815
MAX OUTPUT WATTAGE[W]
10.08
10.20
10.08
10.20
10.08
10.20
10.08
10.20
*1
VOLTAGE[V]
CURRENT[A]
12 or ꢀ24
0.42
15 or ꢀ+0
0.+4
12 or ꢀ24
0.42
15 or ꢀ+0
0.+4
12 or ꢀ24
0.42
15 or ꢀ+0
0.+4
12 or ꢀ24
0.42
15 or ꢀ+0
0.+4
DC OUTPUT
SPECIFICATIONS
MODEL
MGW100512 MGW100515 MGW101212 MGW101215 MGW102412 MGW102415 MGW104812 MGW104815
DC4.5 - 9
DC9 - 18
DC18 - 36
(Surge voltage 50V, 100ms max)
DC36 - 76
(Surge voltage 100V, 100ms max)
VOLTAGE[V]
(Surge voltage 12.5V, 100ms max) (Surge voltage 25V, 100ms max)
INPUT
*2
*2
CURRENT[A]
2.38typ
85typ
2.40typ
85typ
0.97typ
87typ
0.97typ
88typ
0.49typ
87typ
0.49typ
88typ
0.24typ
88typ
0.25typ
88typ
EFFICIENCY[%]
VOLTAGE[V]
12 or ꢀ24
0.42
15 or ꢀ30
0.34
12 or ꢀ24
0.42
15 or ꢀ30
0.34
12 or ꢀ24
0.42
15 or ꢀ30
0.34
12 or ꢀ24
0.42
15 or ꢀ30
0.34
CURRENT[A]
LINE REGULATION[mV]
60max
480max
600max
75max
60max
75max
60max
75max
60max
75max
*3
600max
750max
120max
480max
200max
600max
180max
290max
60max
480max
600max
120max
360max
200max
500max
150max
240max
48max
600max
750max
120max
360max
200max
500max
180max
290max
60max
480max
600max
120max
360max
200max
500max
150max
240max
48max
600max
750max
120max
360max
200max
500max
180max
290max
60max
480max
600max
120max
360max
200max
500max
150max
240max
48max
600max
750max
120max
360max
200max
500max
180max
290max
60max
LOAD REGULATION[mV]
*
4
Po=+0% to 120max
RIPPLE[mVp-p]
*5
Po=0 to +0%
Po=+0% to
480max
200max
600max
OUTPUT
RIPPLE NOISE[mVp-p]
*5
Po=0 to +0%
-20 to ꢀ50C 150max
-40 to ꢀ50C 240max
TEMPERATURE
REGULATION[mV]
*
6
DRIFT[mV]
48max
START-UP TIME[ms]
30max (Minimum input, Io=100%)
11.64 - 12.36 14.55 - 15.45 11.64 - 12.36 14.55 - 15.45 11.64 - 12.36 14.55 - 15.45 11.64 - 12.36 14.55 - 15.45
OUTPUT VOLTAGE SETTING[V]
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
REMOTE ON/OFF
Provided (Negative logic L : ON, H : OFF)
ISOLATION INPUT-OUTPUT
DC1,500V or AC1,000V 1minute, Cutoff current=10mA, DC500V 1,000MWmin (20 15C)
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to ꢀ85C, 20 to 95%RH (Non condensing) (Required derating), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -40 to ꢀ100C, 20 to 95%RH (Non condensing), 9,000m (30,000feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz 98.0m/s (10G), 3minute period, 60minutes each along X, Y and Z axis
2
IMPACT
490.3m/s (50G) 11ms, once each along X, Y and Z axis
SAFETY
OTHERS
AGENCY APPROVALS
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL, EN60950-1
22.0X12.0X9.5mm [0.87X0.48X0.38 inches] (WXHXD) / 7g max
Convection/Forced air
*1 Single output ꢀ24V, ꢀ30V with no use of COM.
*2 Rated input 5V, 12V, 24V or 48V DC Io=100%
*3 Symmetrical loading from 20% to 100%.
*4 Symmetrical loading from 0% to 100%.
*5 Ripple and Ripple Noise is measured by using test board with ceramic capacitor 1 F at
50mm from output pins. (20MHz Osilloscope). Po:Output wattage.
*6 Drift is the DC output accuracy for eight hours period after a half-hour warm-up at 25C.
*
Parallel operation with other model is not possible.
MG-20