Ordering information
DC-DC Converters Bus Converter Power Module Type
DB
S
400
B
03
5
DBS400B
1ꢀ
2ꢀ
3ꢀ
4ꢀ
1Series name
2Single output
3Output wattage
4Input voltage
B :DC200 - 400V
5Output voltage
R
MODEL
DBS400B03 DBS400B05 DBS400B07 DBS400B12 DBS400B15 DBS400B18 DBS400B24 DBS400B28
MAX OUTPUT WATTAGE[W]
DC OUTPUT
264
400
405
408
405
396
408
406
3.3V 80A
5V 80A
7.5V 54A
12V 34A
15V 27A
18V 22A
24V 17A
28V 14.5A
SPECIFICATIONS
MODEL
DBS400B03 DBS400B05 DBS400B07 DBS400B12 DBS400B15 DBS400B18 DBS400B24 DBS400B28
VOLTAGE[V]
DC200 - 400
1
1
*
INPUT
CURRENT[A]
EFFICIENCY[%]
VOLTAGE[V]
1.19typ
79typ
3.3
1.72typ
83typ
1.68typ
86typ
1.67typ
87typ
1.66typ
87typ
1.61typ
89typ
1.67typ
87typ
1.63typ
88typ
*
5
7.5
12
15
18
24
28
CURRENT[A]
80
80
54
34
27
22
17
14.5
LINE REGULATION[mV] 16max
LOAD REGULATION[mV] 30max
20max
40max
80max
140max
100max
150max
50max
85max
20max
30max
60max
100max
150max
140max
160max
75max
130max
30max
40max
100max
120max
160max
150max
180max
120max
200max
40max
60max
150max
120max
160max
150max
180max
180max
310max
60max
60max
150max
120max
160max
150max
180max
180max
310max
60max
95max
190max
120max
160max
150max
180max
280max
480max
90max
95max
190max
120max
160max
150max
180max
280max
480max
90max
2
*
2
*
2
*
2
*
0
to +85
80max
C
RIPPLE[mVp-p]
-20 - 0
140max
100max
150max
C
0
to +85
C
OUTPUT
RIPPLE NOISE[mVp-p]
-20 - 0
C
0 to +65 35max
C
TEMPERATURE REGULATION[mV]
-20 to +85 60max
C
3
*
DRIFT[mV]
16max
(
,
)
START-UP TIME[ms]
200max DCIN 280V Io=100%
),
(
OUTPUT VOLTAGE ADJUSTMENT RANGE Fixed TRM pin open 60 - 110% adjustable by external VR or external voltage
OUTPUT VOLTAGE SETTING[V] 3.25 - 3.45 4.90 - 5.20 7.25 - 7.85 11.60 - 12.60 14.40 - 15.60 17.28 - 18.72 23.04 - 24.96 26.88 - 29.12
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
PROTECTION
CIRCUIT AND
OTHERS
OVERVOLTAGE PROTECTION 4.00 - 5.50V 5.75 - 7.00V 8.60 - 10.50V 13.80 - 16.80V 17.25 - 21.00V 20.70 - 25.20V 27.60 - 33.60V 32.20 - 39.20V
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
Provided
(
)
Provided On both side of input and output
,
,
,
(
)
)
AC3 000V 1minute Cutoff current = 10mA DC500V 50M min 20 15
W
t
C
,
,
,
(
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min 20 15
W
t
C
ISOLATION
, , (
AC500V 1minute Cutoff current = 100mA DC500V 50M min 20 15
W t
)
C
)
OUTPUT-FG
,
, , (
AC100V 1minute Cutoff current = 100mA DC100V 10M min 20 15
W t
OUTPUT-RC2 RC3
C
4
*
,
(
),
(
) (
),
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE
-20 to +85
C
On aluminum base plate 20 - 95%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max
,
,
(
),
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -40 to +85
20 - 95%RH Non condensing 9 000m 30 000feet max
C
ENVIRONMENT
2
,
(
),
,
,
VIBRATION
10 - 55Hz 49.0m/s 5G 3minutes period 60minutes each along X Y and Z axis
IMPACT
196.1m/s2 20G 11ms once each along X Y and Z axis
(
),
,
, , ,
UL60950-1 C-UL EN60950-1 EN50178 Complies with DEN-AN and IEC60950-1
SAFETY
OTHERS
AGENCY APPROVALS
CASE SIZE/WEIGHT
COOLING METHOD
(
)
H D / 180g max
X
61 12.7 116.8mm [2.4 0.5 4.6 inches] W
X
X
X
X
X
(
)
Conduction cooling e.g. heat radiation from the aluminum base plate to the attached heat sink
*1 At rated input(DC280V) and rated load.
*2 Ripple and ripple noise is measured by using measuring board with the recommended capacitor Co & the film capacitor 0.1mF.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:RM101). Refer to the manual.
*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*4 Please consult us in regard to use from -40C.
DBS-6