RC224ATL/224ATLV  
4.0 AT Commands  
EmbeddedModem Family  
Table 4-2. AT Command Set Summary (2 of 5)  
Command  
Sn  
Function  
Default  
Parameters/Description  
Establishes S-Register n as the last register accessed.  
n = v Sets S-Register n to the value v.  
n? Reports the value of S-Register n.  
Select S register as default  
Range: n = 0-27  
n
Sn =  
Sn?  
Parameters: none  
Range: n = 0-27 (register  
no.)  
Writes to an S Register. Sr=x sets register “n” to the value “x”.  
Configuration registers are provided to retain modem  
configuration parameters. The contents of these registers can be  
modified with this command.  
x=0-255 (value)  
Parameters: none  
Range: n = 0-27  
Reads an S register. Sn? causes the contents stored in register  
“n” to be returned.  
T
Force DTMF dialing  
Report codes form  
Vn  
n = 1  
n = 0 Result code is sent as a digit.  
n = 1 Result code is sent as ASCII text.  
Xn  
Extended result codes  
n = 4  
n = 0 Basic set of result codes 0-4 are enabled. The modem  
blind dials and sends the appropriate connect result code  
once a satisfactory connection is established. Dial tone  
and busy are not recognized.  
n = 1 Result codes 0-5 and 10 are enabled. The modem blind  
dials and sends the appropriate connect result code once  
a satisfactory connection is established. Dial tone and  
busy are not recognized.  
n = 2 Result codes 0-6 and 10 are enabled; dial tone detected.  
The modem waits for a dial tone before dialing, then  
sends the appropriate result code once a satisfactory  
connection is established. The busy result code is sent if  
a busy signal is detected.  
n = 3 Result codes 0-5, 7 and 10 are enabled; busy signal  
detected; dial tone not detected. The modem blind dials  
and sends the appropriate connect result code once a  
satisfactory connection is established. The busy result  
code is sent if a busy signal is detected.  
n = 4 Result codes 0-7 and 10 are enabled; busy signal and  
dial tone detected. The modem waits for a dial tone  
before dialing, then sends the appropriate result code  
once a satisfactory connection is established. The NO  
DIALTONE result code is sent if the dial tone is not  
detected within 5 seconds. The BUSY result code is sent  
if a busy signal is detected.  
Yn  
Long space disconnect  
Soft reset and restore profile  
RLSD (DCD) option  
n = 0  
n = 0  
n = 0  
n = 0 Disables long space disconnect.  
n = 1 Enables long space disconnect.  
Zn  
n = 0 Soft reset. Restores stored profile 0.  
n = 1 Soft reset. Restores stored profile 1.  
&Cn  
n = 0 RLSD remains ON at all times.  
n = 1 RLSD follows the state of the carrier.  
D224ATLVDSC  