CN8478/CN8474A/CN8472A/CN8471A  
6.0 Basic Operation  
Multichannel Synchronous Communications Controller (MUSYCC™)  
6.4 Protocol Support  
Change of Frame Alignment  
(COFA) while Transmitting  
HDLC Message  
In the case of change of frame alignment while transmitting an HDLC message  
(T1/E1 modes), the TSYNC input signal transitions from low to high when not  
expected to do so by the frame synchronization flywheel mechanism. This error  
only applies to ports configured for T1, E1, 2xE1 or 4xE1 signals. Frame  
synchronization indicates the location of time slot 0 in the serial data stream.  
Lacking frame synchronization, the transmitter cannot map and align time slots.  
This error affects all active channels in the channel group.  
(T1/E1 modes)  
Reason:  
T1/E1 signal failure is detected by the physical interface providing the  
serial data, clock frequency, and synchronization to the serial interface on  
MUSYCC.  
Effects:  
Causes serial interface to enter COFA mode for one T1/E1 frame period  
(125 µs)—not necessarily on a frame boundary.  
For every activated channel transmitting an HDLC message, the Transmit  
channel enters an abort state where the BLP transmits a repetitive abort  
sequence of 16 consecutive 1s.  
MUSYCC does not update the transmit Message Descriptor and does not  
generate an EOB/EOM unless the message is already sent or the buffer is  
already processed.  
MUSYCC stops polling any active transmit channels descriptor.  
After the COFA condition subsides, the channel is deactivated.  
Channel Level Recovery Actions:  
Transmit channel reactivation is required.  
6.4.8.4 Receive Errors  
Receive errors are service-affecting and require a corrective action by the host to  
resume normal bit-level processing.  
Overflow Due to Host  
Ownership of Buffer while  
Receiving HDLC Message  
(ONR)  
In the case of overflow due to host ownership of the buffer while receiving an  
HDLC message, MUSYCC attempts to access the next Message Descriptor to  
store a message or part of a message, and finds that ownership of the descriptor  
has not been granted by the host.  
This error results when currently receiving an HDLC message, and no  
additional descriptors are available in a timely manner.  
100660E  
Conexant  
6-37  