3.0 Registers  
Bt8370/8375/8376  
3.2 Global Control and Status Registers  
Fully Integrated T1/E1 Framer and Line Interface  
RFRAME[3:0]  
Receiver Framer modeEstablishes the offline framer's search criteria for recovery of frame  
alignment (reframe). Also works in conjunction with the RLOFARLOFD bits [addr 040] to  
establish the online framer's criteria for loss of frame alignment. Refer to  
Table A-1, Superframe Format through Table A-1, Superframe Format to find which frame  
bits are monitored, and refer to Table 2-3, Criteria for Loss/Recovery of Receive Framer  
Alignment for frame alignment loss/recovery criteria during the selected mode. Mode  
descriptions are listed in Table 3-2. The online framers SF, SLC, CAS, and MFAS criteria for  
loss/recovery of multiframe alignment is also selected by RFRAME[3:0].  
Table 3-2. Receive Framer Modes  
RFRAME[3:0]  
T1/E1N  
Receive Framer Mode  
000X  
001X  
010X  
011X  
100X  
101X  
110X  
111X  
0000  
0001  
0100  
0101  
0110  
1000  
1001  
1100  
1101  
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
FAS Only  
FAS Only + BSLIP  
FAS + CRC  
FAS + CRC + BSLIP  
FAS + CAS  
FAS + CAS + BSLIP  
FAS + CRC + CAS  
FAS + CRC + CAS + BSLIP  
FT Only  
ESF + No CRC (FPS only)  
SF  
SF + JYEL  
SF + T1DM  
SLC + FSLOF  
SLC  
ESF + Mimic CRC  
ESF + Force CRC  
T1/E1N  
Global T1/E1 SelectAffects all Bt8370/8375/8376 functions by enabling receive and  
transmit circuits to operate at either the T1 or E1 line rate. The processor must reinitialize all  
control register settings after changing the T1/E1N control bit. T1/E1N selects the nominal  
line rate (shown below), while the exact receive and transmit line rate frequencies are  
independently determined by their respective input clock or data references. The actual receive  
and transmit line frequency can vary within defined tolerances.  
0 = 2.048 MHz line rate (E1)  
1 = 1.544 MHz line rate (T1)  
3-10  
Conexant  
N8370DSE  
 
 