Delta Modulation CODEC
11
MX629
Figure 13: Attenuation Distortion vs. Frequency (32kbps)
6 Performance Specification
6.1 Electrical Performance
6.1.1 Absolute Maximum Ratings
Exceeding these maximum ratings can result in damage to the device.
Min.
Max.
Units
Supply (V - V
)
-0.3
-0.3
7.0
V
V
DD
SS
Voltage on any pin to V
Current
V
+ 0.3
SS
DD
V
V
-30
-30
-20
30
30
20
mA
mA
mA
DD
SS
any other pin
J / P / LH Packages
Total Allowable Power Dissipation at T
Derating above 25°C
= 25°C
-
-
800
10
mW
AMB
mW/°C above 25°C
Storage Temperature
-55
-40
125
85
°C
°C
Operating Temperature
6.1.2 Operating Limits
Correct operation of the device outside these limits is not implied.
Min
Typ.
Max.
Units
V
Supply (V - V
)
SS
4.5
-40
500
5.0
5.5
85
DD
Operating Temperature
Xtal Frequency
°C
1.024
1500
MHz
ꢀ1998 MX-COM, Inc.
www.mxcom.com Tel: 800 638 5577 336 744 5050 Fax: 336 744 5054
Doc. # 20480190.001
4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA
All Trademarks and service marks are held by their respective companies.