Call Progress Tone Detector
FX633
1.3
Signal List
Package
D4
Pin No.
2
Package
P1
Pin No.
1
Name
Signal
Description
Type
I/P
The input to the on-chip oscillator, for external
Xtal circuit or clock.
The inverted output of the on-chip oscillator.
A logic "0" pulse of at least 1µs applied to this
input resets the decoder circuits and forces both
DETECT1 and DETECT2 outputs to a logic "0".
When a call progress signal is detected, this
output goes to a logic "1".
Signal input. Signals to this pin should be ac
coupled. The dc bias of this pin is set internally.
The negative supply rail (ground).
This output is used in conjunction with
DETECT1.
When DETECT1 is at a logic "1", this output
goes to a logic "1" if a Call Progress High Band
signal is detected.
When DETECT1 is at a logic "0", this output
goes to a logic "1" if a Non Call Progress signal
is detected.
XTAL/CLOCK
3
5
2
3
XTALN
ENABLE
O/P
I/P
7
10
12
13
4
5
6
7
DETECT1
SIGIN
Vss
DETECT2
O/P
I/P
Power
O/P
15
8
V
DD
Power
The positive supply rail. This pin should be
decoupled to V
SS
by a capacitor.
Internal Connection. Do not make any
connection to these pins.
1, 4, 6,
8, 9, 11,
14, 16
NC
Notes:
I/P =
O/P =
Input
Output
©
1996 Consumer Microcircuits Limited
4