Tone Detector  
FX105A  
1.6.2.2 Calculate Minimum Usable Bandwidth (%)  
Minimum Usable Bandwidth (MUBW) is the TOTAL (%) bandwidth required for the following:  
(a) Input signal frequency tolerance (Df0)  
(b) FX105A VCO temperature coefficient (TC = - 100ppm/ºC)  
(c)  
FX105A VCO supply voltage coefficient (VC = 2330ppm/V)  
Add (a), (b) and (c) and express as TOTAL (%) bandwidth, not as a ± (%) value.  
MUBW = Df0 + |Tc|DTEMP + VcDVDD  
MUBW = 0.5 + 0.01 x 100 + 0.233 x 1 » 2%  
1.6.2.3 Calculate the Recommended Operating Bandwidth  
Note again that this is the TOTAL (%) bandwidth:  
BW = ½ [10 + MUBW] = ½ (10 + 2) = 6%  
1.6.2.4 Select R2 for Operating BW  
R2 = 4.8 BW/ [10.35 -BW] = 4.8 x 6/ (10.35 -6) » 6.8kW  
The exact bandwidth given by any value of R2 will vary slightly. In applications where an exact  
bandwidth is required, R2 should be a variable resistor to permit adjustment.  
1.6.2.5 Calculate RVC2A (C2A = C2B) Use nearest preferred values  
RVC2A » 100/ [3 f0 BW] » 100/ (3 x 2800 x 6) » 2msec  
Therefore  
RV » 200kW for C2A = C2B = 10nF  
1.6.2.6 Define the Maximum Allowed Response Time  
The maximum response time (TON) is the sum of the VCO lock time (TLOCK) and the Word integration  
time (TWORD). The FX105A’s TON must not exceed the maximum time allowed for the application, but  
a value lying near the maximum gives the best S/N performance.  
(a) Calculate TLOCK  
TLOCK = 150/ [f0 BW] = 150/ (2800 x 6) » 9msec  
Note: TLOCK may vary from near zero to the value given, causing corresponding variations in actual  
TON  
(b) Calculate Maximum Allowable TWORD  
TWORD = TONMAX -TLOCK = 50 - 9 = 41msec  
.
Note: Since the maximum allowed response time (TON) is 50msec, a maximum Word integration time  
of 41msec is available.  
ã 1999 Consumer Microcircuits Limited  