Evaluation Kit for CMX838 Family Radio Processor  
13  
EV8380 User Manual  
CTCSS Tone  
67.0  
Tone Index (hex)  
CTCSS Tone  
156.7  
159.8  
162.2  
165.5  
167.9  
171.3  
173.8  
177.3  
179.9  
183.5  
186.2  
189.9  
192.8  
196.6  
199.5  
203.5  
206.5  
210.7  
218.1  
225.7  
229.1  
233.6  
241.8  
250.3  
254.1  
Tone Index (hex)  
01  
02  
03  
04  
05  
06  
07  
08  
09  
0A  
0B  
0C  
0D  
0E  
0F  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
1A  
1B  
1C  
1D  
1E  
1F  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
2A  
2B  
2C  
2D  
2E  
2F  
30  
31  
32  
69.3  
71.9  
74.4  
77.0  
79.7  
82.5  
85.4  
88.5  
91.5  
94.8  
97.4  
100.0  
103.5  
107.2  
110.9  
114.8  
118.8  
123.0  
127.3  
131.8  
136.5  
141.3  
146.2  
151.4  
$33 = user programmable mode  
$3E = all TIA-603 tones selected  
$3F = all tones selected (user programming and TIA-603)  
Table 2: CMX838 Standard CTCSS Tone Table  
The following information describes important timing aspects of the various operating modes of the tone  
signaling processor:  
1) CMX838 clocks must be properly set up and running before any tasks can be issued to the tone  
signaling processor.  
2) During normal operation, tasks can be issued to the SUBAUDIO PROCESSOR GENERAL CONTROL  
($93) register at a maximum rate of one task every 250µs.  
a. If the tone signaling processor is in its “Fast Initialization” mode, tasks can be issued to the  
SUBAUDIO PROCESSOR GENERAL CONTROL ($93) register at a maximum rate of one task  
every 50µs.  
3) For tasks that involve “argument data” (such as information corresponding to a particular tone), the  
argument data must be loaded into the argument register first. After the argument data has been  
loaded, the appropriate task should then be loaded into the SUBAUDIO PROCESSOR GENERAL  
CONTROL ($93) register.  
a) Once “argument data” has been passed to the argument register, no delay is required before  
writing the corresponding task to the SUBAUDIO PROCESSOR GENERAL CONTROL ($93)  
register.  
4) After a task has been loaded into the SUBAUDIO PROCESSOR GENERAL CONTROL ($93) register,  
a minimum wait time of 250µs must be observed before modifying the contents of any argument data  
register.  
¤2001 MX-COM, Inc.  