Low Voltage SPM Detector
CMX631A
6 Performance Specification
6.1 Electrical Specifications
6.1.1 Absolute Maximum Ratings
Exceeding the maximum rating can result in device damage.
Parameter
Supply Voltage (V -V
Min.
-0.3
-0.3
Typ.
Max.
Unit
V
)
7.0
DD SS
Voltage on any pin to V
Current into ……
(V + 0.3)
DD
V
SS
V
V
-30
-30
-20
30
30
20
mA
mA
mA
DD
SS
Any other pin
D4 / P3 Packages
Min.
Typ.
Typ.
Max.
Unit
800
mW
Total allowable device dissipation at T
25°C
25°C
AMB
13
Derating above T
25°C
mW/°C
AMB
Operating Temperature
Storage Temperature
-40
-40
85
85
°C
°C
D5 Package
Min.
Max.
Unit
550
mW
Total allowable device dissipation at T
AMB
9
Derating above T
25°C
mW/°C
AMB
Operating Temperature
Storage Temperature
-40
-40
85
85
°C
°C
6.1.2 Operating Limits
Correct Operation of the device outside these limits is not implied.
Parameter
Min.
Typ.
Max.
5.5
Unit
Supply Voltage (V
)
DD
2.7
3.0/5.0
V
Operating Temperature
Xtal/Clock Frequency
-40
85
°C
MHz
3.558918
3.589368
ã 1998 Consumer Microcircuits Limited
11
D/631A/1