RALCWI Vocoder  
CMX608/CMX618/CMX638  
Bit 12  
ESTDD  
Encoder STD Detect: If this bit is set to '1', the encoder will try and detect single  
tones in the input audio stream. If a single tone is detected, the encoder will form  
a special STD frame and place the frequency of the detected single tone in the  
EFRAMEDATA register ($38). If a single tone is not detected the audio will be  
passed on to the next stage.  
If this bit is cleared to '0', the encoder will treat the signal as voice and will not  
detect single tones.  
If this bit is set to '1', then the DSTDD bit in the decoder at the other end of the  
channel should also be set to '1'. See section 6.4 for further details.  
Bit 13  
ESTDP  
Encoder STD Priority: Controls the order of the audio processing in the encoder.  
Single tone detection and DTMF detection are separate stages that are performed  
on the input audio stream before being given to the Vocoder to encode.  
If this bit is set to '1', the encoder will first try and detect a single tone before trying  
to detect DTMF.  
If this bit is cleared to '0', the encoder will first try and detect DTMF before a single  
tone.  
This bit is only significant if both ESTDD and EDTMFD bits are set to '1'. If either  
bit is cleared to '0', then the ESTDP bit is ignored.  
Bit 14  
This bit must be cleared to '0' for correct operation.  
Bit 15  
This bit must be cleared to '0' for correct operation.  
EXCODECCMD register address $12  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
External CODEC command word  
This write-only register enables initialisation commands to be sent to an external CODEC.  
The Vocoder device has a FIFO, 16 words deep, to hold initialisation commands for an external  
CODEC. Each write to this register pushes its contents into this FIFO and increments the FIFO  
word counter. After the word has been pushed into the FIFO, bit 15 (RDY) of the STATUS register  
($40) will be set and, if enabled, IRQN will go low. No other C-BUS registers should be read or  
written whilst this operation is in progress.  
When the device is RESET, this FIFO will be empty. Once filled, the contents will remain in the  
FIFO until a RESET or explicitly emptied by writing the ECC_FIFO_CLEAR command to the  
EXCODECCONT register ($0B). This allows the re-use of the initialisation sequence if the  
CODEC needs to be reset for any reason.  
The count of words currently in the FIFO may be read from the ECFIFO register ($24) after this  
command has completed, which is indicated by SVCACK register ($2E) bit 0 being set to '1'.  
After starting the SSP, all the words in the FIFO will be sent to the device. Once all the words are  
sent, the Vocoder device will assume that the CODEC is now running and that all data transferred  
are audio samples.  
2014 CML Microsystems Plc  
48  