CPC7691  
2.9 Protection  
If a power-cross fault occurs with the device in the talk  
state, the current is passed though the break switches  
SW1 and SW2 on to the integrated protection circuit  
but is limited by the dynamic DC current limit response  
of the two break switches. The DC current limit  
specified over temperature is between 80 mA and  
425 mA and the circuitry has a negative temperature  
coefficient. As a result, if the device is subjected to  
extended heating due to a power cross fault condition,  
2.9.1 Diode Bridge/SCR  
The CPC7691 uses a combination of current limited  
break switches, a diode bridge/SCR clamping circuit,  
and a thermal shutdown mechanism to protect the  
SLIC device or other associated circuitry from damage  
during line transient events such as lightning. During a  
positive transient condition, the fault current is  
the measured current into T  
or R  
will decrease  
conducted through the diode bridge to ground via  
LINE  
LINE  
F
. Voltage is clamped to a diode drop above  
as the device temperature increases. If the device  
temperature rises sufficiently, the temperature  
shutdown mechanism will activate and the device will  
enter the all-off state.  
GND  
ground. During a negative transient of 2 to 4 V more  
negative than the voltage source at V , the SCR  
conducts and faults are shunted to F  
or the diode bridge.  
BAT  
via the SCR  
GND  
2.10 Thermal Shutdown  
The thermal shutdown mechanism activates when the  
device die temperature reaches a minimum of 110° C,  
placing the device in the all-off state regardless of  
In order for the SCR to crowbar (or foldback), the  
SCR’s on-voltage (see “Protection Circuitry Electrical  
Specifications” on page 9) must be less than the applied  
logic input. During thermal shutdown events the T  
SD  
voltage at the V  
pin. If the V  
voltage is less  
BAT  
BAT  
pin will output a logic low with a nominal 0 V level. A  
logic high is output from the T pin during normal  
negative than the SCR on-voltage, or if the V  
BAT  
SD  
supply is unable to source the trigger current, the SCR  
will not crowbar.  
operation with a typical output level equal to V  
.
DD  
If presented with a short duration transient such as a  
lightning event, the thermal shutdown feature will  
typically not activate. But in an extended power-cross  
event, the device temperature will rise and the thermal  
shutdown mechanism will activate forcing the switches  
to the all-off state. At this point the current measured  
For power induction or power-cross fault conditions,  
the positive cycle of the transient is clamped to a diode  
drop above ground and the fault current is directed to  
ground. The negative cycle of the transient will cause  
the SCR to conduct when the voltage exceeds the  
V
reference voltage by two to four volts, steering  
BAT  
into T  
or R  
will drop to zero. Once the device  
LINE  
LINE  
the fault current to ground.  
enters thermal shutdown it will remain in the all-off  
state until the temperature of the device drops below  
the de-activation level of the thermal shutdown circuit.  
This permits the device to autonomously return to  
normal operation. If the transient has not passed,  
current will again flow up to the value allowed by the  
dynamic DC current limiting of the switches and  
heating will resume, reactivating the thermal shutdown  
mechanism. This cycle of entering and exiting the  
thermal shutdown mode will continue as long as the  
fault condition persists. If the magnitude of the fault  
condition is great enough, the external secondary  
protector will activate shunting the fault current to  
ground.  
Note: The CPC7691xB does not contain the  
protection SCR but instead uses diodes to clamp both  
polarities of a transient fault. These diodes direct the  
negative potential’s fault current to the V  
pin.  
BAT  
2.9.2 Current Limiting function  
If a lightning strike transient occurs when the device is  
in the talk state, the current is passed along the line to  
the integrated protection circuitry and restricted by the  
dynamic current limit response of the active switches.  
During the talk state when a 1000V 10x1000 μs  
lightning pulse (GR-1089-CORE) is applied to the line  
though a properly clamped external protector, the  
current seen at T  
or R  
will be a pulse with a  
LINE  
LINE  
typical magnitude of 2.5 A and a duration less than  
0.5 μs.  
14  
PRELIMINARY  
R00E  